OSHA SearchOSHA records by employer

FSGC Corp: OSHA inspections and violations

Jamaica, New York · New Single-Family Housing Construction (except For-Sale Builders) · NAICS 236115

1inspections
5citation items
$2,880current penalties
Nov 2, 2015last inspection

OSHA inspectors have visited FSGC Corp in New York one time.

It opened on Nov 2, 2015 as a planned inspection, in Jamaica.

In all, OSHA issued 5 citation items: 5 serious.

The proposed penalties came to $4,800; today they stand at $2,880, 40% less.

The rule cited most here is 1926.451 (scaffolds, general requirements), 4 times.

Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. FSGC Corp averages $2,880 across 1 cited inspection.

FSGC Corp: OSHA citation items per year, 2015 to 2015
Citation items per year, by inspection date.

Want to know if OSHA cites FSGC Corp again? Add it to a watchlist and we will email you the morning the citation shows up.

Watch this company

Inspection history

Inspection 341028728 OPENED NOV 2, 2015Closed

Planned · Partial · Safety · 4 employees at the site · Closed Apr 5, 2017

182-17 Aberdeen Road, Jamaica, NY 11432 · New Single-Family Housing Construction (except For-Sale Builders) · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.102(a)(1) · Eye and face protection in construction
Serious$2,000$1,200Nov 19, 2015Final
Citation 1, item 2a
29 CFR 1926.451(b)(1)(ii) · Scaffolds, general requirements
Serious$2,800$1,680Nov 19, 2015Final
Citation 1, item 2b
29 CFR 1926.451(c)(2) · Scaffolds, general requirements
Serious$0$0Nov 19, 2015Final
Citation 1, item 2c
29 CFR 1926.451(c)(2)(i) · Scaffolds, general requirements
Serious$0$0Nov 19, 2015Final
Citation 1, item 2d
29 CFR 1926.451(g)(1) · Scaffolds, general requirements
Serious$0$0Nov 19, 2015Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.102 · Eye and face protection in construction

29 CFR 1926.102(a)(1)

(a) General. (1) The employer shall ensure that each affected employee uses appropriate eye or face protection when exposed to eye or face hazards from flying particles, molten metal, liquid chemicals, acids or caustic liquids, chemical gases or vapors, or potentially injurious light radiation.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(b)(1)(ii)

(ii) Where the employer makes the demonstration provided for in paragraph (b)(1)(i) of this section, the platform shall be planked or decked as fully as possible and the remaining open space between the platform and the uprights shall not exceed 9 1/2 inches (24.1 cm).

29 CFR 1926.451(c)(2)

(2) Supported scaffold poles, legs, posts, frames, and uprights shall bear on base plates and mud sills or other adequate firm foundation.

Other new single-family housing construction (except for-sale builders) employers in New York

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.