OSHA SearchOSHA records by employer

Furey Roofing and Construction Company, Inc.: OSHA inspections and violations

Newport, Rhode Island · Roofing Contractors · NAICS 238160

8inspections
8citation items
$8,102current penalties
Sep 3, 2020last inspection

Since 1999, OSHA inspectors have visited Furey Roofing and Construction Company, Inc. in Rhode Island 8 times.

The most recent inspection opened on Sep 3, 2020 after a complaint, in Providence.

In all, OSHA issued 8 citation items: 8 serious.

The proposed penalties came to $10,809; today they stand at $8,102, 25% less.

The rule cited most here is 1926.451 (scaffolds, general requirements), 4 times.

Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. Furey Roofing and Construction Company, Inc. averages $2,089 across 1 cited inspection.

Furey Roofing and Construction Company, Inc. also files yearly injury logs with OSHA, summarized below.

Furey Roofing and Construction Company, Inc.: OSHA citation items per year, 1999 to 2020
Citation items per year, by inspection date.

Rhode Island · latest 90 days of OSHA records

79employers cited

8 of them in the same industry

Get notified the morning OSHA posts each new citation in Rhode Island: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Rhode Island

Checking a subcontractor, a client or your own company? Watch Furey Roofing and Construction Company, Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 344919675 OPENED SEP 3, 2020Closed

Complaint · Partial · Safety · 24 employees at the site · Closed Mar 18, 2021

30 Kennedy Plaza, Providence, RI 02903 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.21(b)(2) · Construction safety training
Serious$2,984$2,089Feb 11, 2021Final

Inspection 344277835 OPENED SEP 3, 2019Closed

Referral · Complete · Safety · 23 employees at the site · Closed Nov 4, 2019

1475 Main St. #1, West Warwick, RI 02893 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 343718540 OPENED JAN 15, 2019Closed

Complaint · Partial · Safety · 4 employees at the site · Closed Jan 17, 2019

1072 Main St., West Warwick, RI 02893 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 339834731 OPENED JUL 1, 2014Closed

Planned · Partial · Safety · 50 employees at the site · Closed Sep 11, 2014

Tennis Hall Of Fame, Bellvue Ave., Newport, RI 02840 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 314918806 OPENED AUG 19, 2011Closed

Planned · Partial · Safety · 22 employees at the site · Closed Apr 12, 2016

Division St, East Greenwich, RI 02818 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(1) · Fall protection in construction
Serious$4,200$4,200Sep 13, 2011Final

Inspection 302670005 OPENED OCT 5, 2000Closed

Planned · Partial · Safety · 7 employees at the site · Closed Nov 16, 2000

Post Road, Warwick, RI 02888 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.451(g)(1) · Scaffolds, general requirements
Serious$625$312Oct 19, 2000Closed
Citation 1, item 1b
29 CFR 1926.451(f)(3) · Scaffolds, general requirements
Serious$0$0Oct 19, 2000Closed

Inspection 302669296 OPENED JUL 26, 2000Closed

Planned · Complete · Safety · 6 employees at the site · Closed Aug 25, 2000

300 Spring St, Newport, RI 02840 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(10) · Fall protection in construction
Serious$1,000$500Aug 1, 2000Closed

Inspection 300099710 OPENED JAN 8, 1999Closed

Referral · Complete · Safety · 5 employees at the site · Closed Mar 10, 1999

Jt Connell Rd, Newport, RI 02840 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.451(e)(1) · Scaffolds, general requirements
Serious$1,000$500Feb 12, 1999Closed
Citation 1, item 1b
29 CFR 1926.451(g)(1) · Scaffolds, general requirements
Serious$0$0Feb 12, 1999Closed
Citation 1, item 2
29 CFR 1926.602(c)(1)(vii) · Earthmovers and forklifts in construction
Serious$1,000$500Feb 12, 1999Closed

Injury and illness logs

From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.

In 2024, the Warwick site logged 1 recordable injury or illness among about 24 workers: 3.7 per 100 full-time workers, against a median of 2.8 for its industry.

Site and yearWorkersCasesDays-away casesRateIndustry median
Furey Roofing and Construction Company, Inc.
Warwick · 2024
24 103.72.8

Included with any plan: 8 more yearly logs from these sites, back to 2016, with each site's average rate over its latest three years. Already a subscriber? Sign in.

See plans

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.21 · Construction safety training

29 CFR 1926.21(b)(2)

(2) The employer shall instruct each employee in the recognition and avoidance of unsafe conditions and the regulations applicable to his work environment to control or eliminate any hazards or other exposure to illness or injury.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(e)(1)

(1) When scaffold platforms are more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from another scaffold, structure, personnel hoist, or similar surface shall be used. Crossbraces shall not be used as a means of access.

29 CFR 1926.451(f)(3)

(3) Scaffolds and scaffold components shall be inspected for visible defects by a competent person before each work shift, and after any occurrence which could affect a scaffold's structural integrity.

29 CFR 1926.501 · Fall protection in construction

29 CFR 1926.602 · Earthmovers and forklifts in construction

Other roofing contractors employers in Rhode Island

Alert subscribers get notified of each newly cited employer in Rhode Island the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.