OSHA SearchOSHA records by employer

Fxi, Inc.: OSHA inspections and violations

East Rutherford, New Jersey · Polystyrene Foam Product Manufacturing · NAICS 326140

3inspections
4citation items
$31,778current penalties
Aug 3, 2021last inspection

Since 2018, OSHA inspectors have visited Fxi, Inc. in New Jersey 3 times.

The most recent inspection opened on Aug 3, 2021 to follow up on an earlier case, in East Rutherford.

In all, OSHA issued 4 citation items: 1 serious and 3 other-than-serious.

The proposed penalties came to $34,030; today they stand at $31,778, 7% less.

The rule cited most here is 1910.303 (electrical equipment, general requirements), 2 times.

Among manufacturing employers, the typical cited inspection since 2015 ends with a $4,500 penalty. Fxi, Inc. averages $15,889 across 2 cited inspections.

Fxi, Inc. also files yearly injury logs with OSHA, summarized below.

Fxi, Inc.: OSHA citation items per year, 2018 to 2021
Citation items per year, by inspection date.

New Jersey · latest 90 days of OSHA records

270employers cited

Get notified the morning OSHA posts each new citation in New Jersey: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in New Jersey

Checking a subcontractor, a client or your own company? Watch Fxi, Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 345453963 OPENED AUG 3, 2021Closed

Follow-up · Partial · Health · 33 employees at the site · Closed Jun 13, 2022

13 Manor Rd, East Rutherford, NJ 07073 · Polystyrene Foam Product Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.138(a) · Gloves and hand protection
Other-than-serious$4,505$2,252Dec 17, 2021Final
Citation 2, item 1
29 CFR 1910.303(b)(2) · Electrical equipment, general requirements
Serious$3,005$3,005Dec 17, 2021Final

Inspection 343788659 OPENED FEB 13, 2019Closed

Planned · No inspection · Health · 89 employees at the site · Closed Feb 15, 2019

13 Manor Rd, East Rutherford, NJ 07073 · Polystyrene Foam Product Manufacturing · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 343577110 OPENED NOV 2, 2018Closed

Complaint · Partial · Health · 89 employees at the site · Closed Jun 16, 2022

13 Manor Rd, East Rutherford, NJ 07073 · Polystyrene Foam Product Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.157(g)(2) · Portable fire extinguishers
Other-than-serious$13,260$13,260Mar 25, 2019Final
Citation 1, item 2
29 CFR 1910.303(b)(2) · Electrical equipment, general requirements
Other-than-serious$13,260$13,260Mar 25, 2019Final

Injury and illness logs

From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.

In 2022, the East Rutherford site logged 0 recordable injuries or illnesses among about 10 workers: 0.0 per 100 full-time workers, against a median of 2.6 for its industry.

Site and yearWorkersCasesDays-away casesRateIndustry median
FXI, Inc. - East Rutherford
East Rutherford · 2022
10 000.02.6
FXI - East Rutherford
East Rutherford · 2019
59 101.32.6
FXI-East Rutherford
East Rutherford · 2018
79 000.02.6
FXI, Inc.
East Rutherford · 2017
85 202.22.6

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.138 · Gloves and hand protection

29 CFR 1910.138(a)

(a) General requirements. Employers shall select and require employees to use appropriate hand protection when employees' hands are exposed to hazards such as those from skin absorption of harmful substances; severe cuts or lacerations; severe abrasions; punctures; chemical burns; thermal burns; and harmful temperature extremes.

29 CFR 1910.157 · Portable fire extinguishers

29 CFR 1910.157(g)(2)

(2) The employer shall provide the education required in paragraph (g)(1) of this section upon initial employment and at least annually thereafter.

29 CFR 1910.303 · Electrical equipment, general requirements

29 CFR 1910.303(b)(2)

(2) Installation and use. Listed or labeled equipment shall be installed and used in accordance with any instructions included in the listing or labeling.

Other polystyrene foam product manufacturing employers in New Jersey

Alert subscribers get notified of each newly cited employer in New Jersey the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.