OSHA SearchOSHA records by employer

G-1 Mechanical Inc.: OSHA inspections and violations

Portsmouth, Virginia · Ship Building and Repairing · NAICS 336611

4inspections
7citation items
$5,925current penalties
Nov 23, 2016last inspection

OSHA has inspected G-1 Mechanical Inc. 4 times in Virginia since 2005.

The latest one began on Nov 23, 2016 after a complaint, in Norfolk.

Those inspections ended with 7 citation items: 4 serious and 3 other-than-serious.

Penalties were first proposed at $10,798 and now stand at $5,925, 45% lower after settlements or reviews.

Belts, pulleys and power-transmission parts comes up most often in these citations: 2 items under 1910.219.

How that compares: the median penalty per cited inspection for manufacturing employers since 2015 is $3,600, and G-1 Mechanical Inc. averages $4,000 (1 cited inspection).

G-1 Mechanical Inc.: OSHA citation items per year, 2005 to 2016
Citation items per year, by inspection date.

Virginia · latest 90 days of OSHA records

249employers cited

2 of them in the same industry

Get notified the morning OSHA posts each new citation in Virginia: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Virginia

Checking a subcontractor, a client or your own company? Watch G-1 Mechanical Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 341932648 OPENED NOV 23, 2016Closed

Complaint · Partial · Safety · 200 employees at the site · Closed Aug 30, 2017

General Dynamics - Nassco Norfolk 200 Ligon St. Onboard Uss Oak Hill, Norfolk, VA 23523 · Ship Building and Repairing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1915.56(b)(2) · Arc welding and cutting
Serious$8,873$4,000Apr 13, 2017Final

Inspection 309732931 OPENED OCT 26, 2009Closed

Planned · Complete · Safety · 39 employees at the site · Closed May 30, 2014

416 46th Street, Newport News, VA 23607 · Ship Building and Repairing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.219(d)(1) · Belts, pulleys and power-transmission parts
Serious$1,100$1,100Nov 5, 2009Closed
Citation 1, item 1b
29 CFR 1910.219(e)(1)(i) · Belts, pulleys and power-transmission parts
Serious$0$0Nov 5, 2009Closed
Citation 1, item 2
29 CFR 1910.253(b)(4)(iii) · Gas welding and cutting
Serious$825$825Nov 5, 2009Closed
Citation 2, item 1
29 CFR 1910.37(b)(2) · Exit routes
Other-than-serious$0$0Nov 5, 2009Closed
Citation 2, item 2
29 CFR 1915.152(f)(5) · Personal Protective Equipment (PPE): general requirements
Other-than-serious$0$0Nov 5, 2009Closed
Citation 2, item 3
29 CFR 1915.502(a) · Fire safety plan
Other-than-serious$0$0Nov 5, 2009Closed

Inspection 300200276 OPENED NOV 2, 2005Closed

Planned · No inspection · Safety · Closed Nov 2, 2005

714 Loudoun Ave., Portsmouth, VA 23707 · Ship Building and Repairing · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 300200490 OPENED NOV 2, 2005Closed

Planned · No inspection · Safety · Closed Nov 2, 2005

714 Loudoun Ave, Portsmouth, VA 23707 · Ship Building and Repairing · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.219 · Belts, pulleys and power-transmission parts

29 CFR 1910.219(d)(1)

(d) Pulleys—(1) Guarding. Pulleys, any parts of which are seven (7) feet or less from the floor or working platform, shall be guarded in accordance with the standards specified in paragraphs (m) and (o) of this section. Pulleys serving as balance wheels (e.g., punch presses) on which the point of contact between belt and pulley is more than six feet six inches (6 ft. 6 in.) from the floor or platform may be guarded with a disk covering the spokes.

29 CFR 1910.219(e)(1)(i)

(e) Belt, rope, and chain drives—(1) Horizontal belts and ropes. (i) Where both runs of horizontal belts are seven (7) feet or less from the floor level, the guard shall extend to at least fifteen (15) inches above the belt or to a standard height except that where both runs of a horizontal belt are 42 inches or less from the floor, the belt shall be fully enclosed in accordance with paragraphs (m) and (o) of this section.

29 CFR 1910.253 · Gas welding and cutting

29 CFR 1910.253(b)(4)(iii)

(iii) Oxygen cylinders in storage shall be separated from fuel-gas cylinders or combustible materials (especially oil or grease), a minimum distance of 20 feet (6.1 m) or by a noncombustible barrier at least 5 feet (1.5 m) high having a fire-resistance rating of at least one-half hour.

29 CFR 1910.37 · Exit routes

29 CFR 1915.152 · Personal Protective Equipment (PPE): general requirements

29 CFR 1915.502 · Fire safety plan

29 CFR 1915.56 · Arc welding and cutting

Other ship building and repairing employers in Virginia

Alert subscribers get notified of each newly cited employer in Virginia the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.