OSHA SearchOSHA records by employer

G & B Roofing, Inc.: OSHA inspections and violations

Detroit, Michigan · Roofing Contractors · NAICS 238160

5inspections
16citation items
$1,900current penalties
Oct 12, 2021last inspection

G & B Roofing, Inc. has 5 OSHA inspections on record in Michigan, the first in 2002.

OSHA's last visit started on Oct 12, 2021 as a planned inspection, in Brownstown Township.

Across those inspections OSHA issued 16 citation items: 5 serious and 11 other-than-serious.

OSHA proposed $1,900 in penalties and the amount has not been reduced.

Most often, OSHA cited 4084.132, (3 items).

For context, across all construction employers the median penalty per cited inspection since 2015 is $3,080. G & B Roofing, Inc. averages $1,000 over 1 cited inspection in that time.

G & B Roofing, Inc.: OSHA citation items per year, 2002 to 2021
Citation items per year, by inspection date.

Michigan · latest 90 days of OSHA records

653employers cited

37 of them in the same industry

Get notified the morning OSHA posts each new citation in Michigan: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Michigan

Checking a subcontractor, a client or your own company? Watch G & B Roofing, Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 345577431 OPENED OCT 12, 2021Closed

Planned · Complete · Safety · 2 employees at the site · Closed Jun 5, 2023

Near 25983 King Road, Brownstown Township, MI 48174 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 408.41937(4)
Serious$400$400Nov 15, 2021Final
Citation 1, item 2
29 CFR 1926.501(b)(13) · Fall protection in construction
Serious$400$400Nov 15, 2021Final
Citation 2, item 1
29 CFR 408.41124(5)
Other-than-serious$0$0Nov 15, 2021Final
Citation 2, item 2
29 CFR 408.22349(1)
Other-than-serious$200$200Apr 13, 2023Final

Inspection 317226421 OPENED DEC 27, 2013Closed

Planned · Partial · Safety · 4 employees at the site · Closed Sep 25, 2014

St James St Lot 137, South Lyon, MI 48178 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(13) · Fall protection in construction
Serious$200$200Apr 16, 2014Closed
Citation 2, item 1 Other-than-serious$0$0Apr 16, 2014Closed
Citation 2, item 2 Other-than-serious$0$0Apr 16, 2014Closed
Citation 2, item 3 Other-than-serious$0$0Apr 16, 2014Closed
Citation 2, item 4 Other-than-serious$200$200Apr 16, 2014Closed

Inspection 313306961 OPENED JAN 14, 2010Closed

Planned · Partial · Safety · 4 employees at the site · Closed Sep 15, 2010

White Tail Ct Lot 27, Commerce Twp, MI 48382 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1 Other-than-serious$0$0Feb 16, 2010Closed
Citation 1, item 2
29 CFR 1926.502(k)(1) · Fall protection systems
Other-than-serious$0$0Feb 16, 2010Closed

Inspection 308898691 OPENED FEB 13, 2009Closed

Planned · Partial · Safety · 2 employees at the site · Closed Feb 2, 2010

24323 Glenda, Novi, MI 48375 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(11) · Fall protection in construction
Serious$250$250Apr 2, 2009Closed

Inspection 304896699 OPENED OCT 8, 2002Closed

Planned · Complete · Safety · 3 employees at the site · Closed Aug 12, 2003

1730 Magnolia, Detroit, MI 48202 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1 Serious$150$150Nov 22, 2002Closed
Citation 2, item 1 Other-than-serious$0$0Nov 22, 2002Closed
Citation 2, item 2 Other-than-serious$0$0Nov 22, 2002Closed
Citation 3, item 1 Other-than-serious$100$100Apr 9, 2003Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.501 · Fall protection in construction

29 CFR 1926.501(b)(11)

(11) Steep roofs. Each employee on a steep roof with unprotected sides and edges 6 feet (1.8 m) or more above lower levels shall be protected from falling by guardrail systems with toeboards, safety net systems, or personal fall arrest systems.

29 CFR 1926.501(b)(13)

(13) Residential construction. Each employee engaged in residential construction activities 6 feet (1.8 m) or more above lower levels shall be protected by guardrail systems, safety net system, or personal fall arrest system unless another provision in paragraph (b) of this section provides for an alternative fall protection measure. Exception: When the employer can demonstrate that it is infeasible or creates a greater hazard to use these systems, the employer shall develop and implement a fall protection plan which meets the requirements of paragraph (k) of § 1926.502.

29 CFR 1926.502 · Fall protection systems

29 CFR 1926.502(k)(1)

(1) The fall protection plan shall be prepared by a qualified person and developed specifically for the site where the leading edge work, precast concrete work, or residential construction work is being performed and the plan must be maintained up to date.

29 CFR 4082.2349

29 CFR 4084.114

29 CFR 4084.1213

29 CFR 4084.132

Other roofing contractors employers in Michigan

Alert subscribers get notified of each newly cited employer in Michigan the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.