OSHA SearchOSHA records by employer

G&C Masonry LLC: OSHA inspections and violations

South Amboy, New Jersey · Masonry Contractors · NAICS 238140

1inspections
3citation items
$5,655current penalties
Jan 16, 2018last inspection

OSHA inspectors have visited G&C Masonry LLC in New Jersey one time.

It opened on Jan 16, 2018 after a complaint, in South Amboy.

In all, OSHA issued 3 citation items: 3 serious.

The proposed penalties came to $9,424; today they stand at $5,655, 40% less.

The rule cited most here is 1926.451 (scaffolds, general requirements), 3 times.

Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. G&C Masonry LLC averages $5,655 across 1 cited inspection.

G&C Masonry LLC: OSHA citation items per year, 2018 to 2018
Citation items per year, by inspection date.

New Jersey · latest 90 days of OSHA records

276employers cited

9 of them in the same industry

Get notified the morning OSHA posts each new citation in New Jersey: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in New Jersey

Checking a subcontractor, a client or your own company? Watch G&C Masonry LLC and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 342892213 OPENED JAN 16, 2018Closed

Complaint · Partial · Safety · 6 employees at the site · Closed Aug 1, 2019

100 Celecki Drive, South Amboy, NJ 08879 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(e)(1) · Scaffolds, general requirements
Serious$2,772$1,662Feb 23, 2018Final
Citation 1, item 2
29 CFR 1926.451(f)(7) · Scaffolds, general requirements
Serious$2,772$1,665Feb 23, 2018Final
Citation 1, item 3
29 CFR 1926.451(g)(1)(vii) · Scaffolds, general requirements
Serious$3,880$2,328Feb 23, 2018Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(e)(1)

(1) When scaffold platforms are more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from another scaffold, structure, personnel hoist, or similar surface shall be used. Crossbraces shall not be used as a means of access.

29 CFR 1926.451(f)(7)

(7) Scaffolds shall be erected, moved, dismantled, or altered only under the supervision and direction of a competent person qualified in scaffold erection, moving, dismantling or alteration. Such activities shall be performed only by experienced and trained employees selected for such work by the competent person.

29 CFR 1926.451(g)(1)(vii)

(vii) For all scaffolds not otherwise specified in paragraphs (g)(1)(i) through (g)(1)(vi) of this section, each employee shall be protected by the use of personal fall arrest systems or guardrail systems meeting the requirements of paragraph (g)(4) of this section.