OSHA SearchOSHA records by employer

G & J Town Construction Inc: OSHA inspections and violations

Chesapeake, Virginia · New Single-Family Housing Construction (except For-Sale Builders) · NAICS 236115

1inspections
11citation items
$3,339current penalties
Dec 16, 2015last inspection

OSHA has inspected G & J Town Construction Inc once in Virginia.

The inspection began on Dec 16, 2015, in Chesapeake.

That inspection ended with 11 citation items: 10 serious and 1 other-than-serious.

Penalties were first proposed at $14,220 and now stand at $3,339, 77% lower after settlements or reviews.

Scaffolds, general requirements comes up most often in these citations: 5 items under 1926.451.

How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,080, and G & J Town Construction Inc averages $3,339 (1 cited inspection).

G & J Town Construction Inc: OSHA citation items per year, 2015 to 2015
Citation items per year, by inspection date.

Virginia · latest 90 days of OSHA records

253employers cited

2 of them in the same industry

Get notified the morning OSHA posts each new citation in Virginia: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Virginia

Checking a subcontractor, a client or your own company? Watch G & J Town Construction Inc and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 341125581 OPENED DEC 16, 2015Closed

Unprogrammed other · Partial · Safety · 7 employees at the site · Closed Jan 17, 2017

1132 George Olah Drive, Chesapeake, VA 23322 · New Single-Family Housing Construction (except For-Sale Builders) · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.404(f)(6) · Ground-fault protection on job sites
Serious$1,440$1,008Feb 16, 2016Final
Citation 1, item 2a
29 CFR 1926.451(a)(1) · Scaffolds, general requirements
Serious$1,890$1,323Feb 16, 2016Final
Citation 1, item 2b
29 CFR 1926.451(b)(7) · Scaffolds, general requirements
Serious$1,890$0Feb 16, 2016Final
Citation 1, item 2c
29 CFR 1926.451(c)(2) · Scaffolds, general requirements
Serious$1,890$0Feb 16, 2016Final
Citation 1, item 2d
29 CFR 1926.451(g)(1)(vii) · Scaffolds, general requirements
Serious$1,890$0Feb 16, 2016Final
Citation 1, item 2e
29 CFR 1926.451(h)(1) · Scaffolds, general requirements
Serious$1,890$0Feb 16, 2016Final
Citation 1, item 2f
29 CFR 1926.452(j)(2) · Rules for each type of scaffold
Serious$1,890$0Feb 16, 2016Final
Citation 1, item 2g
29 CFR 1926.454(b)(2) · Scaffold training
Serious$0$0Feb 16, 2016Final
Citation 1, item 9a
29 CFR 1926.50(c) · Medical services and first aid
Serious$1,440$1,008Feb 16, 2016Final
Citation 1, item 9b
29 CFR 1926.50(d)(1) · Medical services and first aid
Serious$0$0Feb 16, 2016Final
Citation 2, item 1
29 CFR 1926.150(c)(1)(i) · Fire protection
Other-than-serious$0$0Feb 16, 2016Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.150 · Fire protection

29 CFR 1926.150(c)(1)(i)

(c) Portable firefighting equipment—(1) Fire extinguishers and small hose lines. (i) A fire extinguisher, rated not less than 2A, shall be provided for each 3,000 square feet of the protected building area, or major fraction thereof. Travel distance from any point of the protected area to the nearest fire extinguisher shall not exceed 100 feet.

29 CFR 1926.404 · Ground-fault protection on job sites

29 CFR 1926.404(f)(6)

(6) Grounding path. The path to ground from circuits, equipment, and enclosures shall be permanent and continuous.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(a)(1)

(a) Capacity. (1) Except as provided in paragraphs (a)(2), (a)(3), (a)(4), (a)(5) and (g) of this section, each scaffold and scaffold component shall be capable of supporting, without failure, its own weight and at least 4 times the maximum intended load applied or transmitted to it.

29 CFR 1926.452 · Rules for each type of scaffold

29 CFR 1926.454 · Scaffold training

29 CFR 1926.50 · Medical services and first aid

Other new single-family housing construction (except for-sale builders) employers in Virginia

Alert subscribers get notified of each newly cited employer in Virginia the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.