OSHA SearchOSHA records by employer

G G & S Construction: OSHA inspections and violations

Mc Kinney, Texas · Masonry Contractors · NAICS 238140

3inspections
8citation items
$16,278current penalties
Apr 6, 2018last inspection

G G & S Construction has 3 OSHA inspections on record in Texas, the first in 2014.

OSHA's last visit started on Apr 6, 2018 on a referral, in Mckinney.

Across those inspections OSHA issued 8 citation items: 1 serious and 7 other-than-serious.

OSHA proposed $38,722 in penalties. After settlements and reviews the total is $16,278, down 58%.

Most often, OSHA cited 1926.451, scaffolds, general requirements (6 items).

For context, across all construction employers the median penalty per cited inspection since 2015 is $3,080. G G & S Construction averages $5,899 over 2 cited inspections in that time.

G G & S Construction: OSHA citation items per year, 2014 to 2018
Citation items per year, by inspection date.

Texas · latest 90 days of OSHA records

401employers cited

14 of them in the same industry

Get notified the morning OSHA posts each new citation in Texas: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Texas

Checking a subcontractor, a client or your own company? Watch G G & S Construction and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 343070488 OPENED APR 6, 2018Closed

Referral · Partial · Safety · 20 employees at the site · Closed Jul 23, 2018

3801 S Hardin Blvd, Mckinney, TX 75069 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Incident on Apr 3, 2018: Employee falls from scaffold and fractures back

At 11:00 a.m. on April 3, 2018, Employee #1, employed by a construction company, was engaged in exterior masonry at the construction site for a commercial building. He was working from a Non-Stop Scaffold and installing wall ties along the planks when he fell, a fall height of approximately 20 feet. Emergency services were called, and Employee #1 was transported to the hospital. He was admitted and treated for fractures to his back and chest.

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 2a
29 CFR 1926.451(c)(3) · Scaffolds, general requirements
Other-than-serious$11,641$8,500Jun 15, 2018Final
Citation 1, item 2b
29 CFR 1926.452(c)(2) · Rules for each type of scaffold
Other-than-serious$11,641$0Jun 15, 2018Final

Inspection 342960853 OPENED FEB 14, 2018Closed

Planned · Partial · Safety · 200 employees at the site · Closed Mar 23, 2018

245 W. State Hwy 114, Southlake, TX 76092 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(h)(2)(ii) · Scaffolds, general requirements
Serious$4,240$3,298Feb 21, 2018Final

Inspection 339985616 OPENED OCT 3, 2014Closed

Unprogrammed other · Partial · Safety · 5 employees at the site · Closed Apr 15, 2015

1509 W University, Mc Kinney, TX 75069 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(c)(2)(i) · Scaffolds, general requirements
Other-than-serious$2,800$1,120Nov 10, 2014Final
Citation 1, item 2a
29 CFR 1926.451(g)(1)(vii) · Scaffolds, general requirements
Other-than-serious$2,800$1,120Nov 10, 2014Final
Citation 1, item 2b
29 CFR 1926.451(g)(4)(i) · Scaffolds, general requirements
Other-than-serious$0$0Nov 10, 2014Final
Citation 1, item 3
29 CFR 1926.451(h)(1) · Scaffolds, general requirements
Other-than-serious$2,800$1,120Nov 10, 2014Final
Citation 1, item 4
29 CFR 1926.454(a) · Scaffold training
Other-than-serious$2,800$1,120Nov 10, 2014Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(c)(2)(i)

(i) Footings shall be level, sound, rigid, and capable of supporting the loaded scaffold without settling or displacement.

29 CFR 1926.451(c)(3)

(3) Supported scaffold poles, legs, posts, frames, and uprights shall be plumb and braced to prevent swaying and displacement.

29 CFR 1926.451(g)(1)(vii)

(vii) For all scaffolds not otherwise specified in paragraphs (g)(1)(i) through (g)(1)(vi) of this section, each employee shall be protected by the use of personal fall arrest systems or guardrail systems meeting the requirements of paragraph (g)(4) of this section.

29 CFR 1926.452 · Rules for each type of scaffold

29 CFR 1926.454 · Scaffold training

Other masonry contractors employers in Texas

Alert subscribers get notified of each newly cited employer in Texas the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.