Gabbidon Builders, LLC: OSHA inspections and violations

Waxhaw, North Carolina · New Multifamily Housing Construction (except For-Sale Builders) · NAICS 236116

1inspections
3citation items
$2,730current penalties
Jan 16, 2019last inspection

OSHA inspectors have visited Gabbidon Builders, LLC in North Carolina one time.

It opened on Jan 16, 2019 as a planned inspection, in Waxhaw.

In all, OSHA issued 3 citation items: 3 serious.

The proposed penalties came to $4,200; today they stand at $2,730, 35% less.

The rule cited most here is 1926.451 (scaffolds, general requirements), 3 times.

Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. Gabbidon Builders, LLC averages $2,730 across 1 cited inspection.

Gabbidon Builders, LLC: OSHA citation items per year, 2019 to 2019
Citation items per year, by inspection date.

North Carolina · latest 90 days of OSHA records

230employers cited

Get notified the morning OSHA posts each new citation in North Carolina: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in North Carolina

Checking a subcontractor, a client or your own company? Watch Gabbidon Builders, LLC and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 343721957 OPENED JAN 16, 2019Closed

Planned · Partial · Safety · 1 employee at the site · Closed Oct 13, 2023

Providence Downs South, Riva Ridge Ln Lot 348, Waxhaw, NC 28173 · New Multifamily Housing Construction (except For-Sale Builders) · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.451(b)(1)(i) · Scaffolds, general requirements
Serious$2,100$1,365Mar 27, 2019Final
Citation 1, item 1b
29 CFR 1926.451(g)(1)(vii) · Scaffolds, general requirements
Serious$0$0Mar 27, 2019Final
Citation 1, item 2
29 CFR 1926.451(e)(1) · Scaffolds, general requirements
Serious$2,100$1,365Mar 27, 2019Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(b)(1)(i)

(i) Each platform unit (e.g., scaffold plank, fabricated plank, fabricated deck, or fabricated platform) shall be installed so that the space between adjacent units and the space between the platform and the uprights is no more than 1 inch (2.5 cm) wide, except where the employer can demonstrate that a wider space is necessary (for example, to fit around uprights when side brackets are used to extend the width of the platform).

29 CFR 1926.451(e)(1)

(1) When scaffold platforms are more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from another scaffold, structure, personnel hoist, or similar surface shall be used. Crossbraces shall not be used as a means of access.

29 CFR 1926.451(g)(1)(vii)

(vii) For all scaffolds not otherwise specified in paragraphs (g)(1)(i) through (g)(1)(vi) of this section, each employee shall be protected by the use of personal fall arrest systems or guardrail systems meeting the requirements of paragraph (g)(4) of this section.