OSHA SearchOSHA records by employer

Gabriel Esquivel: OSHA inspections and violations

Royse City, Texas · Masonry Contractors · NAICS 238140

1inspections
4citation items
$14,064current penalties
Mar 6, 2023last inspection

OSHA inspectors have visited Gabriel Esquivel in Texas one time.

It opened on Mar 6, 2023 as a planned inspection, in Royse City.

In all, OSHA issued 4 citation items: 4 serious.

The penalties, $14,064 in total, stand where OSHA first set them.

The rule cited most here is 1926.451 (scaffolds, general requirements), 4 times.

Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. Gabriel Esquivel averages $14,064 across 1 cited inspection.

Gabriel Esquivel: OSHA citation items per year, 2023 to 2023
Citation items per year, by inspection date.

Texas · latest 90 days of OSHA records

393employers cited

13 of them in the same industry

Get notified the morning OSHA posts each new citation in Texas: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Texas

Checking a subcontractor, a client or your own company? Watch Gabriel Esquivel and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 346545593 OPENED MAR 6, 2023Closed

Planned · Partial · Safety · 3 employees at the site · Closed Jun 16, 2026

2613 Green River, Royse City, TX 75189 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.451(b)(1) · Scaffolds, general requirements
Serious$4,688$4,688May 24, 2023Final
Citation 1, item 1b
29 CFR 1926.451(g)(1) · Scaffolds, general requirements
Serious$0$0May 24, 2023Final
Citation 1, item 2
29 CFR 1926.451(c)(2)(iii) · Scaffolds, general requirements
Serious$4,688$4,688May 24, 2023Final
Citation 1, item 3
29 CFR 1926.451(e)(1) · Scaffolds, general requirements
Serious$4,688$4,688May 24, 2023Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(b)(1)

(b) Scaffold platform construction. (1) Each platform on all working levels of scaffolds shall be fully planked or decked between the front uprights and the guardrail supports as follows:

29 CFR 1926.451(c)(2)(iii)

(iii) Unstable objects shall not be used as working platforms.

29 CFR 1926.451(e)(1)

(1) When scaffold platforms are more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from another scaffold, structure, personnel hoist, or similar surface shall be used. Crossbraces shall not be used as a means of access.