OSHA SearchOSHA records by employer

Gagnon Masonry and Excavating: OSHA inspections and violations

Eagle River, Alaska · Masonry Contractors · NAICS 238140

1inspections
8citation items
$8,524current penalties
Jul 1, 2019last inspection

Gagnon Masonry and Excavating has one OSHA inspection on record in Alaska.

OSHA opened it on Jul 1, 2019 as a planned inspection, in Eagle River, and the case has not closed yet.

From that inspection OSHA issued 8 citation items: 6 serious and 2 other-than-serious.

OSHA proposed $8,524 in penalties and the amount has not been reduced.

Most often, OSHA cited 1926.451, scaffolds, general requirements (4 items).

For context, across all construction employers the median penalty per cited inspection since 2015 is $3,080. Gagnon Masonry and Excavating averages $8,524 over 1 cited inspection in that time.

Gagnon Masonry and Excavating: OSHA citation items per year, 2019 to 2019
Citation items per year, by inspection date.

Alaska · latest 90 days of OSHA records

37employers cited

Get notified the morning OSHA posts each new citation in Alaska: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Alaska

Checking a subcontractor, a client or your own company? Watch Gagnon Masonry and Excavating and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 344127055 OPENED JUL 1, 2019Open

Planned · Partial · Safety · 4 employees at the site · Open

Old Glenn And N Juanita Lp, Eagle River, AK 99577 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(g)(1) · Scaffolds, general requirements
Serious$2,273$2,273Sep 20, 2019Final
Citation 1, item 2a
29 CFR 1926.451(b)(1)(i) · Scaffolds, general requirements
Serious$2,273$2,273Sep 20, 2019Final
Citation 1, item 2b
29 CFR 1926.451(e)(1) · Scaffolds, general requirements
Serious$0$0Sep 20, 2019Final
Citation 1, item 2c
29 CFR 1926.451(c)(2) · Scaffolds, general requirements
Serious$0$0Sep 20, 2019Final
Citation 1, item 3
29 CFR 1926.503(a)(1) · Fall protection training in construction
Serious$2,273$2,273Sep 20, 2019Final
Citation 1, item 4
29 CFR 1926.701(b) · Concrete and Masonry Construction: general requirements
Serious$1,705$1,705Sep 20, 2019Final
Citation 2, item 1
29 CFR 1926.602(d) · Earthmovers and forklifts in construction
Other-than-serious$0$0Sep 20, 2019Final
Citation 2, item 2
29 CFR 1926.706(a)(1) · Requirements for masonry construction
Other-than-serious$0$0Sep 20, 2019Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(b)(1)(i)

(i) Each platform unit (e.g., scaffold plank, fabricated plank, fabricated deck, or fabricated platform) shall be installed so that the space between adjacent units and the space between the platform and the uprights is no more than 1 inch (2.5 cm) wide, except where the employer can demonstrate that a wider space is necessary (for example, to fit around uprights when side brackets are used to extend the width of the platform).

29 CFR 1926.451(c)(2)

(2) Supported scaffold poles, legs, posts, frames, and uprights shall bear on base plates and mud sills or other adequate firm foundation.

29 CFR 1926.451(e)(1)

(1) When scaffold platforms are more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from another scaffold, structure, personnel hoist, or similar surface shall be used. Crossbraces shall not be used as a means of access.

29 CFR 1926.503 · Fall protection training in construction

29 CFR 1926.602 · Earthmovers and forklifts in construction

29 CFR 1926.701 · Concrete and Masonry Construction: general requirements

29 CFR 1926.706 · Requirements for masonry construction

Other masonry contractors employers in Alaska