OSHA SearchOSHA records by employer

Galindo Masonry: OSHA inspections and violations

Lewisville, Texas · Masonry Contractors · NAICS 238140

1inspections
3citation items
$5,544current penalties
Mar 13, 2018last inspection

OSHA has inspected Galindo Masonry once in Texas.

The inspection began on Mar 13, 2018 as a planned inspection, in Lewisville.

That inspection ended with 3 citation items: 3 serious.

Penalties were first proposed at $5,544 and still stand at $5,544.

Scaffolds, general requirements comes up most often in these citations: 3 items under 1926.451.

How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,080, and Galindo Masonry averages $5,544 (1 cited inspection).

Galindo Masonry: OSHA citation items per year, 2018 to 2018
Citation items per year, by inspection date.

Want to know if OSHA cites Galindo Masonry again? Add it to a watchlist and we will email you the morning the citation shows up.

Watch this company

Inspection history

Inspection 343014056 OPENED MAR 13, 2018Closed

Planned · Partial · Safety · 7 employees at the site · Closed Jul 11, 2022

1620 Fm 544, Lot 2, Lewisville, TX 75056 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.451(e)(1) · Scaffolds, general requirements
Serious$2,772$2,772Mar 14, 2018Final
Citation 1, item 1b
29 CFR 1926.451(f)(3) · Scaffolds, general requirements
Serious$0$0Mar 14, 2018Final
Citation 1, item 2
29 CFR 1926.451(g)(1)(v) · Scaffolds, general requirements
Serious$2,772$2,772Mar 14, 2018Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(e)(1)

(1) When scaffold platforms are more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from another scaffold, structure, personnel hoist, or similar surface shall be used. Crossbraces shall not be used as a means of access.

29 CFR 1926.451(f)(3)

(3) Scaffolds and scaffold components shall be inspected for visible defects by a competent person before each work shift, and after any occurrence which could affect a scaffold's structural integrity.

29 CFR 1926.451(g)(1)(v)

(v) Each employee on a walkway located within a scaffold shall be protected by a guardrail system (with minimum 200 pound toprail capacity) installed within 9 1/2 inches (24.1 cm) of and along at least one side of the walkway.

Other masonry contractors employers in Texas

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.