OSHA SearchOSHA records by employer

Garage Julio: OSHA inspections and violations

Mayaguez, Puerto Rico · Automotive Body, Paint, and Interior Repair and Maintenance · NAICS 811121

1inspections
15citation items
$2,250current penalties
Jul 6, 2017last inspection

OSHA inspectors have visited Garage Julio in Puerto Rico one time.

It opened on Jul 6, 2017 after a complaint, in Mayaguez.

In all, OSHA issued 15 citation items: 12 serious and 3 other-than-serious.

The proposed penalties came to $4,350; today they stand at $2,250, 48% less.

The rule cited most here is 1910.134 (respiratory protection), 4 times.

Among repair and personal services employers, the typical cited inspection since 2015 ends with a $1,200 penalty. Garage Julio averages $2,250 across 1 cited inspection.

Garage Julio: OSHA citation items per year, 2017 to 2017
Citation items per year, by inspection date.

Puerto Rico · latest 90 days of OSHA records

109employers cited

Get notified the morning OSHA posts each new citation in Puerto Rico: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Puerto Rico

Checking a subcontractor, a client or your own company? Watch Garage Julio and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 342449337 OPENED JUL 6, 2017Closed

Complaint · Partial · Safety · 8 employees at the site · Closed Dec 22, 2017

Carr. 114 Km 1.3 Guanajibo Castillo, Mayaguez, PR 00680 · Automotive Body, Paint, and Interior Repair and Maintenance · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 6 A
Serious$750$375Aug 11, 2017Final
Citation 1, item 1b
29 CFR 6 A
Serious$0$0Aug 11, 2017Final
Citation 1, item 2a
29 CFR 1910.106(e)(2)(iii) · Flammable liquids
Serious$600$300Aug 11, 2017Final
Citation 1, item 2b
29 CFR 1910.106(e)(6)(ii) · Flammable liquids
Serious$0$0Aug 11, 2017Final
Citation 1, item 3a
29 CFR 1910.134(c)(1) · Respiratory protection
Serious$750$450Aug 11, 2017Final
Citation 1, item 3b
29 CFR 1910.134(e)(1) · Respiratory protection
Serious$0$0Aug 11, 2017Final
Citation 1, item 3c
29 CFR 1910.134(f)(2) · Respiratory protection
Serious$0$0Aug 11, 2017Final
Citation 1, item 3d
29 CFR 1910.134(k)(3) · Respiratory protection
Serious$0$0Aug 11, 2017Final
Citation 1, item 4a
29 CFR 1910.1200(e)(1) · Hazard communication
Serious$1,050$525Aug 11, 2017Final
Citation 1, item 4b
29 CFR 1910.1200(f)(5) · Hazard communication
Serious$0$0Aug 11, 2017Final
Citation 1, item 4c
29 CFR 1910.1200(h)(1) · Hazard communication
Serious$0$0Aug 11, 2017Final
Citation 1, item 5
29 CFR 1910.253(b)(4)(iii) · Gas welding and cutting
Serious$600$300Aug 11, 2017Final
Citation 2, item 1
29 CFR 6 B
Other-than-serious$0$0Aug 11, 2017Final
Citation 2, item 2
29 CFR 17 IV B 1
Other-than-serious$600$300Aug 11, 2017Final
Citation 2, item 3
29 CFR 1910.106(f)(6) · Flammable liquids
Other-than-serious$0$0Aug 11, 2017Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.106 · Flammable liquids

29 CFR 1910.106(e)(2)(iii)

(iii) Separation and protection. Areas in which flammable liquids are transferred from one tank or container to another container shall be separated from other operations in the building by adequate distance or by construction having adequate fire resistance. Drainage or other means shall be provided to control spills. Adequate natural or mechanical ventilation shall be provided.

29 CFR 1910.106(e)(6)(ii)

(ii) Grounding. Category 1 or 2 flammable liquids, or Category 3 flammable liquids with a flashpoint below 100 °F (37.8 °C), shall not be dispensed into containers unless the nozzle and container are electrically interconnected. Where the metallic floorplate on which the container stands while filling is electrically connected to the fill stem or where the fill stem is bonded to the container during filling operations by means of a bond wire, the provisions of this section shall be deemed to have been complied with.

29 CFR 1910.106(f)(6)

(6) Sources of ignition. Category 1 or 2 flammable liquids, or Category 3 flammable liquids with a flashpoint below 100 °F (37.8 °C), shall not be handled, drawn, or dispensed where flammable vapors may reach a source of ignition. Smoking shall be prohibited except in designated localities. “No Smoking” signs shall be conspicuously posted where hazard from flammable liquid vapors is normally present.

29 CFR 1910.1200 · Hazard communication

29 CFR 1910.134 · Respiratory protection

29 CFR 1910.253 · Gas welding and cutting

Other automotive body, paint, and interior repair and maintenance employers in Puerto Rico

Alert subscribers get notified of each newly cited employer in Puerto Rico the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.