OSHA SearchOSHA records by employer

Garcia Stucco: OSHA inspections and violations

Houston, Texas · Masonry Contractors · NAICS 238140

3inspections
15citation items
$23,504current penalties
May 19, 2017last inspection

Since 2004, OSHA inspectors have visited Garcia Stucco in Texas 3 times.

The most recent inspection opened on May 19, 2017, in Houston.

In all, OSHA issued 15 citation items: 15 serious.

The proposed penalties came to $25,406; today they stand at $23,504, 7% less.

The rule cited most here is 1926.451 (scaffolds, general requirements), 12 times.

Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. Garcia Stucco averages $8,452 across 2 cited inspections.

Garcia Stucco: OSHA citation items per year, 2004 to 2017
Citation items per year, by inspection date.

Texas · latest 90 days of OSHA records

391employers cited

13 of them in the same industry

Get notified the morning OSHA posts each new citation in Texas: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Texas

Checking a subcontractor, a client or your own company? Watch Garcia Stucco and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 342339041 OPENED MAY 19, 2017Closed

Programmed other · Partial · Safety · 5 employees at the site · Closed Jan 9, 2019

2103 Argonne Unit A, Houston, TX 77019 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.451(c)(1)(ii) · Scaffolds, general requirements
Serious$3,803$1,901Jun 9, 2017Final
Citation 1, item 3
29 CFR 1926.451(g)(1)(vii) · Scaffolds, general requirements
Serious$3,803$3,803Jun 9, 2017Final

Inspection 340989185 OPENED OCT 15, 2015Closed

Planned · Partial · Safety · 4 employees at the site · Closed Sep 13, 2019

151 Players Circle, South Lake, TX 76092 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.100(a) · Hard hats in construction
Serious$1,200$1,200Dec 2, 2015Final
Citation 1, item 2
29 CFR 1926.416(e)(1) · Electrical safety in construction
Serious$1,600$1,600Dec 2, 2015Final
Citation 1, item 3a
29 CFR 1926.451(b)(1) · Scaffolds, general requirements
Serious$2,800$2,800Dec 2, 2015Final
Citation 1, item 3b
29 CFR 1926.451(b)(1)(i) · Scaffolds, general requirements
Serious$0$0Dec 2, 2015Final
Citation 1, item 3c
29 CFR 1926.451(e)(1) · Scaffolds, general requirements
Serious$0$0Dec 2, 2015Final
Citation 1, item 4
29 CFR 1926.451(c)(2) · Scaffolds, general requirements
Serious$2,800$2,800Dec 2, 2015Final
Citation 1, item 5
29 CFR 1926.451(g)(1)(vii) · Scaffolds, general requirements
Serious$2,800$2,800Dec 2, 2015Final

Inspection 306567306 OPENED FEB 18, 2004Closed

Planned · Complete · Safety · 12 employees at the site · Closed Jun 24, 2008

4408 Blossom, Houston, TX 77007 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.95(a) · Criteria for personal protective equipment
Serious$600$600Apr 1, 2004Closed
Citation 1, item 2
29 CFR 1926.451(b)(1) · Scaffolds, general requirements
Serious$1,500$1,500Apr 1, 2004Closed
Citation 1, item 3
29 CFR 1926.451(e)(1) · Scaffolds, general requirements
Serious$750$750Apr 1, 2004Closed
Citation 1, item 4
29 CFR 1926.451(e)(5)(i) · Scaffolds, general requirements
Serious$1,500$1,500Apr 1, 2004Closed
Citation 1, item 5
29 CFR 1926.451(f)(3) · Scaffolds, general requirements
Serious$750$750Apr 1, 2004Closed
Citation 1, item 6
29 CFR 1926.451(g)(1)(vii) · Scaffolds, general requirements
Serious$1,500$1,500Apr 1, 2004Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.100 · Hard hats in construction

29 CFR 1926.100(a)

(a) Employees working in areas where there is a possible danger of head injury from impact, or from falling or flying objects, or from electrical shock and burns, shall be protected by protective helmets.

29 CFR 1926.416 · Electrical safety in construction

29 CFR 1926.416(e)(1)

(e) Cords and cables. (1) Worn or frayed electric cords or cables shall not be used.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(b)(1)

(b) Scaffold platform construction. (1) Each platform on all working levels of scaffolds shall be fully planked or decked between the front uprights and the guardrail supports as follows:

29 CFR 1926.95 · Criteria for personal protective equipment

Other masonry contractors employers in Texas

Alert subscribers get notified of each newly cited employer in Texas the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.