OSHA SearchOSHA records by employer

Garden Villa Hotel: OSHA inspections and violations

Tamuning, Guam · Hotels (except Casino Hotels) and Motels · NAICS 721110

3inspections
19citation items
$21,494current penalties
Apr 20, 2022last inspection

Since 2013, OSHA inspectors have visited Garden Villa Hotel in Guam 3 times.

The most recent inspection opened on Apr 20, 2022 as a planned inspection, in Tamuning.

In all, OSHA issued 19 citation items: 14 serious, 2 repeat and 3 other-than-serious.

The proposed penalties came to $28,781; today they stand at $21,494, 25% less.

The rule cited most here is 1910.1200 (hazard communication), 7 times.

Among hotel and restaurant employers, the typical cited inspection since 2015 ends with a $1,350 penalty. Garden Villa Hotel averages $7,874 across 2 cited inspections.

Garden Villa Hotel: OSHA citation items per year, 2013 to 2022
Citation items per year, by inspection date.

Guam · latest 90 days of OSHA records

6employers cited

Get notified the morning OSHA posts each new citation in Guam: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Guam

Checking a subcontractor, a client or your own company? Watch Garden Villa Hotel and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 345907539 OPENED APR 20, 2022Closed

Planned · Complete · Safety · 33 employees at the site · Closed Jul 3, 2023

800 Pale San Vitores Rd., Tamuning, GU 96913 · Hotels (except Casino Hotels) and Motels · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.212(a)(5) · Machine guarding
Serious$3,698$2,589Jun 15, 2022Final
Citation 1, item 2
29 CFR 1910.305(j)(1)(i) · Electrical wiring methods
Serious$4,351$3,045Jun 15, 2022Final
Citation 2, item 1
29 CFR 1910.1200(e)(1)(i) · Hazard communication
Repeat$290$290Jun 15, 2022Final
Citation 2, item 2
29 CFR 1910.1200(g)(8) · Hazard communication
Repeat$2,901$2,901Jun 15, 2022Final

Inspection 342753951 OPENED OCT 31, 2017Closed

Planned · Partial · Safety · 42 employees at the site · Closed May 17, 2018

800 Pale San Vitores Rd., Tamuning, GU 96913 · Hotels (except Casino Hotels) and Motels · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.134(c)(1) · Respiratory protection
Serious$3,297$2,308Apr 6, 2018Final
Citation 1, item 1b
29 CFR 1910.134(c)(3) · Respiratory protection
Serious$0$0Apr 6, 2018Final
Citation 1, item 1c
29 CFR 1910.134(e)(1) · Respiratory protection
Serious$0$0Apr 6, 2018Final
Citation 1, item 1d
29 CFR 1910.134(f)(1) · Respiratory protection
Serious$0$0Apr 6, 2018Final
Citation 1, item 2a
29 CFR 1910.147(c)(1) · Lockout/tagout
Serious$3,297$2,308Apr 6, 2018Final
Citation 1, item 2b
29 CFR 1910.147(c)(7)(i)(a) · Lockout/tagout
Serious$0$0Apr 6, 2018Final
Citation 1, item 3a
29 CFR 1910.1200(e)(1)(i) · Hazard communication
Serious$3,297$2,308Apr 6, 2018Final
Citation 1, item 3b
29 CFR 1910.1200(g)(8) · Hazard communication
Serious$0$0Apr 6, 2018Final

Inspection 339003956 OPENED APR 12, 2013Closed

Planned · Complete · Safety · 98 employees at the site · Closed Jul 16, 2013

800 Pale San Vitores Rd., Tamuning, GU 96913 · Hotels (except Casino Hotels) and Motels · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.106(d)(2)(i) · Flammable liquids
Serious$2,550$1,915Jun 17, 2013Final
Citation 1, item 1b
29 CFR 1910.106(e)(2)(ii) · Flammable liquids
Serious$0$0Jun 17, 2013Final
Citation 1, item 2
29 CFR 1910.305(b)(2)(i) · Electrical wiring methods
Serious$2,550$1,915Jun 17, 2013Final
Citation 1, item 3
29 CFR 1910.1200(f)(5) · Hazard communication
Serious$2,550$1,915Jun 17, 2013Final
Citation 2, item 1
29 CFR 1910.134(h)(2)(i) · Respiratory protection
Other-than-serious$0$0Jun 17, 2013Final
Citation 2, item 2
29 CFR 1910.1200(e)(1)(i) · Hazard communication
Other-than-serious$0$0Jun 17, 2013Final
Citation 2, item 3
29 CFR 1910.1200(g)(1) · Hazard communication
Other-than-serious$0$0Jun 17, 2013Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.106 · Flammable liquids

29 CFR 1910.106(d)(2)(i)

(2) Design, construction, and capacity of containers—(i) General. Only approved containers and portable tanks shall be used. Metal containers and portable tanks meeting the requirements of and containing products authorized by chapter I, title 49 of the Code of Federal Regulations (regulations issued by the Hazardous Materials Regulations Board, Department of Transportation), shall be deemed to be acceptable.

29 CFR 1910.106(e)(2)(ii)

(ii) Containers. Flammable liquids shall be stored in tanks or closed containers.

29 CFR 1910.1200 · Hazard communication

29 CFR 1910.1200(e)(1)(i)

(i) A list of the hazardous chemicals known to be present using a product identifier that is referenced on the appropriate safety data sheet (the list may be compiled for the workplace as a whole or for individual work areas); and,

29 CFR 1910.134 · Respiratory protection

29 CFR 1910.147 · Lockout/tagout

29 CFR 1910.212 · Machine guarding

29 CFR 1910.305 · Electrical wiring methods

Other hotels (except casino hotels) and motels employers in Guam

Alert subscribers get notified of each newly cited employer in Guam the morning it is posted. See the alert plans.