OSHA SearchOSHA records by employer

Garner Concrete Construction LLC: OSHA inspections and violations

Denver, Colorado · Siding Contractors · NAICS 238170

1inspections
6citation items
$8,672current penalties
Jun 7, 2023last inspection

OSHA inspectors have visited Garner Concrete Construction LLC in Colorado one time.

It opened on Jun 7, 2023 as a planned inspection, in Denver.

In all, OSHA issued 6 citation items: 6 serious.

The penalties, $8,672 in total, stand where OSHA first set them.

The rule cited most here is 1926.451 (scaffolds, general requirements), 6 times.

Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. Garner Concrete Construction LLC averages $8,672 across 1 cited inspection.

Garner Concrete Construction LLC: OSHA citation items per year, 2023 to 2023
Citation items per year, by inspection date.

Colorado · latest 90 days of OSHA records

136employers cited

3 of them in the same industry

Get notified the morning OSHA posts each new citation in Colorado: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Colorado

Checking a subcontractor, a client or your own company? Watch Garner Concrete Construction LLC and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 346752371 OPENED JUN 7, 2023Closed

Planned · Partial · Safety · 4 employees at the site · Closed Mar 16, 2026

2567 Emerson St., Denver, CO 80218 · Siding Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.451(f)(7) · Scaffolds, general requirements
Serious$4,688$4,688Nov 7, 2023Final
Citation 1, item 1b
29 CFR 1926.451(b)(1) · Scaffolds, general requirements
Serious$0$0Nov 7, 2023Final
Citation 1, item 1c
29 CFR 1926.451(b)(10) · Scaffolds, general requirements
Serious$0$0Nov 7, 2023Final
Citation 1, item 1d
29 CFR 1926.451(c)(2) · Scaffolds, general requirements
Serious$0$0Nov 7, 2023Final
Citation 1, item 1e
29 CFR 1926.451(e)(1) · Scaffolds, general requirements
Serious$0$0Nov 7, 2023Final
Citation 1, item 2
29 CFR 1926.451(g)(1) · Scaffolds, general requirements
Serious$3,984$3,984Nov 7, 2023Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(b)(1)

(b) Scaffold platform construction. (1) Each platform on all working levels of scaffolds shall be fully planked or decked between the front uprights and the guardrail supports as follows:

29 CFR 1926.451(b)(10)

(10) Scaffold components manufactured by different manufacturers shall not be intermixed unless the components fit together without force and the scaffold's structural integrity is maintained by the user. Scaffold components manufactured by different manufacturers shall not be modified in order to intermix them unless a competent person determines the resulting scaffold is structurally sound.

29 CFR 1926.451(c)(2)

(2) Supported scaffold poles, legs, posts, frames, and uprights shall bear on base plates and mud sills or other adequate firm foundation.

Other siding contractors employers in Colorado

Alert subscribers get notified of each newly cited employer in Colorado the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.