OSHA SearchOSHA records by employer

Gator Fabrication LLC: OSHA inspections and violations

Conroe, Texas · Oil and Gas Pipeline and Related Structures Construction · NAICS 237120

1inspections
3citation items
$7,560current penalties
Jan 15, 2015last inspection

OSHA inspectors have visited Gator Fabrication LLC in Texas one time.

It opened on Jan 15, 2015 after a complaint, in Conroe.

In all, OSHA issued 3 citation items: 3 serious.

The penalties, $7,560 in total, stand where OSHA first set them.

Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. Gator Fabrication LLC averages $7,560 across 1 cited inspection.

Gator Fabrication LLC: OSHA citation items per year, 2015 to 2015
Citation items per year, by inspection date.

Texas · latest 90 days of OSHA records

391employers cited

3 of them in the same industry

Get notified the morning OSHA posts each new citation in Texas: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Texas

Checking a subcontractor, a client or your own company? Watch Gator Fabrication LLC and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 340182674 OPENED JAN 15, 2015Closed

Complaint · Partial · Safety · 30 employees at the site · Closed Aug 12, 2015

101 E Avenue M, Conroe, TX 77301 · Oil and Gas Pipeline and Related Structures Construction · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.101(b) · Compressed gases (general requirements)
Serious$2,800$2,800Mar 25, 2015Final
Citation 1, item 2
29 CFR 1910.253(b)(4)(iii) · Gas welding and cutting
Serious$2,380$2,380Mar 25, 2015Final
Citation 1, item 3
29 CFR 1910.305(g)(2)(iii) · Electrical wiring methods
Serious$2,380$2,380Mar 25, 2015Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.101 · Compressed gases (general requirements)

29 CFR 1910.101(b)

(b) Compressed gases. The in-plant handling, storage, and utilization of all compressed gases in cylinders, portable tanks, rail tankcars, or motor vehicle cargo tanks shall be in accordance with Compressed Gas Association Pamphlet P-1-1965, which is incorporated by reference as specified in § 1910.6.

29 CFR 1910.253 · Gas welding and cutting

29 CFR 1910.253(b)(4)(iii)

(iii) Oxygen cylinders in storage shall be separated from fuel-gas cylinders or combustible materials (especially oil or grease), a minimum distance of 20 feet (6.1 m) or by a noncombustible barrier at least 5 feet (1.5 m) high having a fire-resistance rating of at least one-half hour.

29 CFR 1910.305 · Electrical wiring methods

29 CFR 1910.305(g)(2)(iii)

(iii) Flexible cords and cables shall be connected to devices and fittings so that strain relief is provided that will prevent pull from being directly transmitted to joints or terminal screws.

Other oil and gas pipeline and related structures construction employers in Texas

Alert subscribers get notified of each newly cited employer in Texas the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.