Inspection 342695392 OPENED OCT 11, 2017Closed
3447 80th Avenue Se, Jamestown, ND 58401 · Nitrogenous Fertilizer Manufacturing · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Jamestown, North Dakota · Nitrogenous Fertilizer Manufacturing · NAICS 325311
Gavilon Fertilizer, LLC has 2 OSHA inspections on record in North Dakota, the first in 2017.
OSHA's last visit started on Oct 11, 2017 after a complaint, in Jamestown.
Across those inspections OSHA issued 2 citation items: 2 other-than-serious.
OSHA proposed $5,543 in penalties. After settlements and reviews the total is $2,772, down 50%.
Most often, OSHA cited 1910.119, process safety management (2 items).
For context, across all manufacturing employers the median penalty per cited inspection since 2015 is $4,500. Gavilon Fertilizer, LLC averages $2,772 over 1 cited inspection in that time.
North Dakota · latest 90 days of OSHA records
30employers cited
Get notified the morning OSHA posts each new citation in North Dakota: the employer, the site address, the rules broken and the penalty.
See who gets cited nextLatest cited in North Dakota
Checking a subcontractor, a client or your own company? Watch Gavilon Fertilizer, LLC and get notified the morning OSHA posts a new citation for it.
Watch this company3447 80th Avenue Se, Jamestown, ND 58401 · Nitrogenous Fertilizer Manufacturing · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
3447 80th Avenue Se, Jamestown, ND 58401 · Nitrogenous Fertilizer Manufacturing · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.119(j)(5) · Process safety management |
Other-than-serious | $5,543 | $2,772 | Feb 8, 2018 | Final |
| Citation 1, item 2 29 CFR 1910.119(d)(3)(i)(b) · Process safety management |
Other-than-serious | $0 | $0 | Feb 8, 2018 | Final |
Current text from the Code of Federal Regulations. Some citations were issued under older wording.
29 CFR 1910.119(d)(3)(i)(b)
(B) Piping and instrument diagrams (P&ID's);
29 CFR 1910.119(j)(5)
(5) Equipment deficiencies. The employer shall correct deficiencies in equipment that are outside acceptable limits (defined by the process safety information in paragraph (d) of this section) before further use or in a safe and timely manner when necessary means are taken to assure safe operation.
Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.