OSHA SearchOSHA records by employer

Gea Heat Exchangers, Incorporated, Phe Division: OSHA inspections and violations

York, Pennsylvania · Power Boiler and Heat Exchanger Manufacturing · NAICS 332410

2inspections
13citation items
$14,657current penalties
Oct 29, 2015last inspection

Gea Heat Exchangers, Incorporated, Phe Division has 2 OSHA inspections on record in Pennsylvania, the first in 2012.

OSHA's last visit started on Oct 29, 2015 after a complaint, in York.

Across those inspections OSHA issued 13 citation items: 9 serious and 4 other-than-serious.

OSHA proposed $22,550 in penalties. After settlements and reviews the total is $14,657, down 35%.

Most often, OSHA cited 1910.147, lockout/tagout (2 items).

For context, across all manufacturing employers the median penalty per cited inspection since 2015 is $3,600. Gea Heat Exchangers, Incorporated, Phe Division averages $0 over 1 cited inspection in that time.

Gea Heat Exchangers, Incorporated, Phe Division: OSHA citation items per year, 2012 to 2015
Citation items per year, by inspection date.

Pennsylvania · latest 90 days of OSHA records

280employers cited

Get notified the morning OSHA posts each new citation in Pennsylvania: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Pennsylvania

Checking a subcontractor, a client or your own company? Watch Gea Heat Exchangers, Incorporated, Phe Division and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 341024339 OPENED OCT 29, 2015Closed

Complaint · Partial · Safety · 120 employees at the site · Closed May 20, 2016

100 Gea Drive, York, PA 17406 · Power Boiler and Heat Exchanger Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.133(b)(1) · Eye and face protection
Other-than-serious$0$0Apr 13, 2016Final

Inspection 336114780 OPENED AUG 21, 2012Closed

Planned · Complete · Health · 156 employees at the site · Closed Mar 15, 2013

100 Gea Drive, York, PA 17406 · Power Boiler and Heat Exchanger Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1 Serious$5,000$3,250Feb 19, 2013Final
Citation 1, item 2a
29 CFR 1910.106(e)(6)(i) · Flammable liquids
Serious$2,550$1,657Feb 19, 2013Final
Citation 1, item 2b
29 CFR 1910.106(e)(6)(ii) · Flammable liquids
Serious$0$0Feb 19, 2013Final
Citation 1, item 3
29 CFR 1910.137(b)(2)(viii) · Electrical protective equipment
Serious$3,000$1,950Feb 19, 2013Final
Citation 1, item 4a Serious$3,000$1,950Feb 19, 2013Final
Citation 1, item 4b
29 CFR 1910.147(c)(6)(i) · Lockout/tagout
Serious$0$0Feb 19, 2013Final
Citation 1, item 4c
29 CFR 1910.333(b)(2)(i) · Working near live electrical parts
Serious$0$0Feb 19, 2013Final
Citation 1, item 5
29 CFR 1910.212(a)(3)(ii) · Machine guarding
Serious$5,000$3,250Feb 19, 2013Final
Citation 1, item 6
29 CFR 1910.1200(h)(3)(ii) · Hazard communication
Serious$4,000$2,600Feb 19, 2013Final
Citation 2, item 1a
29 CFR 1910.134(c)(1) · Respiratory protection
Other-than-serious$0$0Feb 19, 2013Final
Citation 2, item 1b
29 CFR 1910.134(m)(2)(i) · Respiratory protection
Other-than-serious$0$0Feb 19, 2013Final
Citation 2, item 2
29 CFR 1910.1026(d)(2)(i) · Hexavalent chromium
Other-than-serious$0$0Feb 19, 2013Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.1026 · Hexavalent chromium

29 CFR 1910.1026(d)(2)(i)

(2) Scheduled monitoring option. (i) The employer shall perform initial monitoring to determine the 8-hour TWA exposure for each employee on the basis of a sufficient number of personal breathing zone air samples to accurately characterize full shift exposure on each shift, for each job classification, in each work area. Where an employer does representative sampling instead of sampling all employees in order to meet this requirement, the employer shall sample the employee(s) expected to have the highest chromium (VI) exposures.

29 CFR 1910.106 · Flammable liquids

29 CFR 1910.106(e)(6)(i)

(6) Sources of ignition—(i) General. Adequate precautions shall be taken to prevent the ignition of flammable vapors. Sources of ignition include but are not limited to open flames; lightning; smoking; cutting and welding; hot surfaces; frictional heat; static, electrical, and mechanical sparks; spontaneous ignition, including heat-producing chemical reactions; and radiant heat.

29 CFR 1910.106(e)(6)(ii)

(ii) Grounding. Category 1 or 2 flammable liquids, or Category 3 flammable liquids with a flashpoint below 100 °F (37.8 °C), shall not be dispensed into containers unless the nozzle and container are electrically interconnected. Where the metallic floorplate on which the container stands while filling is electrically connected to the fill stem or where the fill stem is bonded to the container during filling operations by means of a bond wire, the provisions of this section shall be deemed to have been complied with.

29 CFR 1910.1200 · Hazard communication

29 CFR 1910.133 · Eye and face protection

29 CFR 1910.134 · Respiratory protection

29 CFR 1910.137 · Electrical protective equipment

29 CFR 1910.147 · Lockout/tagout

29 CFR 1910.212 · Machine guarding

29 CFR 1910.333 · Working near live electrical parts

29 CFR 1910.95 · Noise

Other power boiler and heat exchanger manufacturing employers in Pennsylvania

Alert subscribers get notified of each newly cited employer in Pennsylvania the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.