Inspection 348724550 OPENED JAN 30, 2026Closed
Milford St., Upton, MA 01568 · Water and Sewer Line and Related Structures Construction · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Longmeadow, Massachusetts · Water and Sewer Line and Related Structures Construction · NAICS 237110
Geg Construction, Inc has 9 OSHA inspections on record in Massachusetts, the first in 2013.
OSHA's last visit started on Jan 30, 2026 as a planned inspection, in Upton.
Across those inspections OSHA issued 7 citation items: 2 serious, 3 repeat and 2 other-than-serious.
OSHA proposed $70,169 in penalties. After settlements and reviews the total is $23,244, down 67%.
Most often, OSHA cited 1926.652, trench protection (4 items).
For context, across all construction employers the median penalty per cited inspection since 2015 is $3,080. Geg Construction, Inc averages $5,462 over 2 cited inspections in that time.
Massachusetts · latest 90 days of OSHA records
247employers cited
6 of them in the same industry
Get notified the morning OSHA posts each new citation in Massachusetts: the employer, the site address, the rules broken and the penalty.
See who gets cited nextLatest cited in Massachusetts
Checking a subcontractor, a client or your own company? Watch Geg Construction, Inc and get notified the morning OSHA posts a new citation for it.
Watch this companyMilford St., Upton, MA 01568 · Water and Sewer Line and Related Structures Construction · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Boulder Drive, Fitchburg, MA 01420 · Water and Sewer Line and Related Structures Construction · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Lake St, Webster, MA 01570 · Water and Sewer Line and Related Structures Construction · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Marble St, Athol, MA 01331 · Water and Sewer Line and Related Structures Construction · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
F/o 260 Main St, East Longmeadow, MA 01028 · Water and Sewer Line and Related Structures Construction · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1a 29 CFR 1926.1053(b)(1) · Ladders in construction |
Other-than-serious | $5,691 | $0 | Jun 11, 2018 | Final |
| Citation 1, item 1b 29 CFR 1926.1053(b)(16) · Ladders in construction |
Other-than-serious | $0 | $0 | Jun 11, 2018 | Final |
| Citation 2, item 1 29 CFR 1926.652(a)(1) · Trench protection |
Serious | $28,455 | $2,956 | Jun 11, 2018 | Final |
Maple St, East Longmeadow, MA 01028 · Water and Sewer Line and Related Structures Construction · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1926.652(a)(1) · Trench protection |
Repeat | $11,383 | $7,968 | Feb 22, 2018 | Final |
C/o Laurel & Bliss Rd(s), Longmeadow, MA 01106 · Water and Sewer Line and Related Structures Construction · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
1587 Longmeadow St, Longmeadow, MA 01106 · Water and Sewer Line and Related Structures Construction · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1926.652(a)(1) · Trench protection |
Repeat | $15,400 | $7,700 | May 27, 2014 | Final |
C/o Williams St & Merriweather, Longmeadow, MA 01106 · Water and Sewer Line and Related Structures Construction · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1926.651(c)(2) · Excavations |
Serious | $3,080 | $1,540 | Sep 27, 2013 | Final |
| Citation 2, item 1 29 CFR 1926.652(a)(1) · Trench protection |
Repeat | $6,160 | $3,080 | Sep 27, 2013 | Final |
Current text from the Code of Federal Regulations. Some citations were issued under older wording.
29 CFR 1926.1053(b)(1)
(1) When portable ladders are used for access to an upper landing surface, the ladder side rails shall extend at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access; or, when such an extension is not possible because of the ladder's length, then the ladder shall be secured at its top to a rigid support that will not deflect, and a grasping device, such as a grabrail, shall be provided to assist employees in mounting and dismounting the ladder. In no case shall the extension be such that ladder deflection under a load would, by itself, cause the ladder to slip off its support.
29 CFR 1926.1053(b)(16)
(16) Portable ladders with structural defects, such as, but not limited to, broken or missing rungs, cleats, or steps, broken or split rails, corroded components, or other faulty or defective components, shall either be immediately marked in a manner that readily identifies them as defective, or be tagged with “Do Not Use” or similar language, and shall be withdrawn from service until repaired.
29 CFR 1926.651(c)(2)
(2) Means of egress from trench excavations. A stairway, ladder, ramp or other safe means of egress shall be located in trench excavations that are 4 feet (1.22 m) or more in depth so as to require no more than 25 feet (7.62 m) of lateral travel for employees.
Alert subscribers get notified of each newly cited employer in Massachusetts the morning it is posted. See the alert plans.
Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.