OSHA SearchOSHA records by employer

Gem Mechanical LLC: OSHA inspections and violations

New York City, New York · Masonry Contractors · NAICS 238140

1inspections
3citation items
$5,704current penalties
Feb 16, 2017last inspection

OSHA has inspected Gem Mechanical LLC once in New York.

The inspection began on Feb 16, 2017 as a planned inspection, in New York City.

That inspection ended with 3 citation items: 3 serious.

Penalties were first proposed at $7,606 and now stand at $5,704, 25% lower after settlements or reviews.

How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,080, and Gem Mechanical LLC averages $5,704 (1 cited inspection).

Gem Mechanical LLC: OSHA citation items per year, 2017 to 2017
Citation items per year, by inspection date.

New York · latest 90 days of OSHA records

356employers cited

6 of them in the same industry

Get notified the morning OSHA posts each new citation in New York: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in New York

Checking a subcontractor, a client or your own company? Watch Gem Mechanical LLC and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 342147782 OPENED FEB 16, 2017Closed

Planned · Partial · Safety · 5 employees at the site · Closed Sep 22, 2017

733 Amsterdam Ave, New York City, NY 10004 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.350(a)(9) · Gas welding and cutting
Serious$2,173$1,630Jun 3, 2017Final
Citation 1, item 2
29 CFR 1926.352(e) · Fire prevention
Serious$1,630$1,222Jun 3, 2017Final
Citation 1, item 3
29 CFR 1926.451(g)(4)(iv) · Scaffolds, general requirements
Serious$3,803$2,852Jun 3, 2017Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.350 · Gas welding and cutting

29 CFR 1926.350(a)(9)

(9) Compressed gas cylinders shall be secured in an upright position at all times except, if necessary, for short periods of time while cylinders are actually being hoisted or carried.

29 CFR 1926.352 · Fire prevention

29 CFR 1926.352(e)

(e) When the welding, cutting, or heating operation is such that normal fire prevention precautions are not sufficient, additional personnel shall be assigned to guard against fire while the actual welding, cutting, or heating operation is being performed, and for a sufficient period of time after completion of the work to ensure that no possibility of fire exists. Such personnel shall be instructed as to the specific anticipated fire hazards and how the firefighting equipment provided is to be used.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(g)(4)(iv)

(iv) When midrails are used, they shall be installed at a height approximately midway between the top edge of the guardrail system and the platform surface.