OSHA SearchOSHA records by employer

General Cable Corporation: OSHA inspections and violations

Lincoln, Rhode Island · Other Communication and Energy Wire Manufacturing · NAICS 335929

3inspections
2citation items
$3,613current penalties
Mar 6, 2015last inspection

OSHA has inspected General Cable Corporation 3 times in Rhode Island since 2009.

The latest one began on Mar 6, 2015 on a referral, in Lincoln.

Those inspections ended with 2 citation items: 1 serious and 1 other-than-serious.

Penalties were first proposed at $3,613 and still stand at $3,613.

How that compares: the median penalty per cited inspection for manufacturing employers since 2015 is $3,600, and General Cable Corporation averages $3,613 (1 cited inspection).

It reported 2 severe injuries to OSHA since 2015.

The Wage and Hour Division has 1 case on it since 2015, with $0 in back wages owed to workers.

General Cable Corporation: OSHA citation items per year, 2009 to 2015
Citation items per year, by inspection date.

Rhode Island · latest 90 days of OSHA records

85employers cited

Get notified the morning OSHA posts each new citation in Rhode Island: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Rhode Island

Checking a subcontractor, a client or your own company? Watch General Cable Corporation and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 340447820 OPENED MAR 6, 2015Closed

Referral · Partial · Safety · 200 employees at the site · Closed Sep 10, 2015

3 Carol Drive, Lincoln, RI 02865 · Other Communication and Energy Wire Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.212(a)(1) · Machine guarding
Serious$3,613$3,613Aug 6, 2015Final

Inspection 312343585 OPENED OCT 14, 2009Closed

Complaint · Partial · Safety · 180 employees at the site · Closed Feb 23, 2010

3 Carol Drive, Lincoln, RI 02865 · Other Communication and Energy Wire Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.303(g)(1)(ii) · Electrical equipment, general requirements
Other-than-serious$0$0Nov 27, 2009Closed

Inspection 312341126 OPENED MAR 27, 2009Closed

Complaint · Partial · Safety · 200 employees at the site · Closed Mar 27, 2009

3 Carol Drive, Lincoln, RI 02865 · Other Communication and Energy Wire Manufacturing · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Severe injury reports

Employers must report any work-related amputation, in-patient hospitalization or loss of an eye to OSHA within 24 hours. 2 reports on file.

Aug 27, 2020, Lincoln: Amputation · amputations · finger(s), fingernail(s), unspecified

An employee was setting up a machine and feeding marking thread through the die to prepare for startup. The employee's right middle fingertip was crushed, resulting in a partial amputation.

Mar 4, 2015, Lincoln: Amputation · amputations · fingertip(s)

Employee sustained an amputation of the right pinky fingertip while loading a wooden reel onto a pack line. His right little finger was crushed between the flange and the reel.

Wage and hour cases

Cases by the Labor Department's Wage and Hour Division since 2015: unpaid minimum wage or overtime, child labor, family leave and more.

Period reviewedViolationsWorkers owedBack wagesPenalties
Apr 24, 2016 to Apr 29, 2018
Lincoln
20$0$0

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.212 · Machine guarding

29 CFR 1910.212(a)(1)

(a) Machine guarding—(1) Types of guarding. One or more methods of machine guarding shall be provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks. Examples of guarding methods are—barrier guards, two-hand tripping devices, electronic safety devices, etc.

29 CFR 1910.303 · Electrical equipment, general requirements

29 CFR 1910.303(g)(1)(ii)

(ii) Working space required by this standard may not be used for storage. When normally enclosed live parts are exposed for inspection or servicing, the working space, if in a passageway or general open space, shall be suitably guarded.

Other other communication and energy wire manufacturing employers in Rhode Island

Alert subscribers get notified of each newly cited employer in Rhode Island the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.