Inspection 345143515 OPENED FEB 10, 2021Closed
600 Martin Luther King Jr. Place Suite 273, Louisville, KY 40202 · Lessors of Other Real Estate Property · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Louisville, Kentucky · Lessors of Other Real Estate Property · NAICS 531190
Since 2019, OSHA inspectors have visited General Services Administration (Gsa) in Kentucky 3 times.
The most recent inspection opened on Feb 10, 2021 after a complaint, in Louisville.
In all, OSHA issued 6 citation items: 5 serious and 1 other-than-serious.
No penalty came with these citations.
The rule cited most here is 1910.29 (fall protection systems in general industry), 2 times.
Among real estate and rental employers, the typical cited inspection since 2015 ends with a $1,864 penalty. General Services Administration (Gsa) averages $0 across 1 cited inspection.
Kentucky · latest 90 days of OSHA records
180employers cited
Get notified the morning OSHA posts each new citation in Kentucky: the employer, the site address, the rules broken and the penalty.
See who gets cited nextLatest cited in Kentucky
Checking a subcontractor, a client or your own company? Watch General Services Administration (Gsa) and get notified the morning OSHA posts a new citation for it.
Watch this company600 Martin Luther King Jr. Place Suite 273, Louisville, KY 40202 · Lessors of Other Real Estate Property · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
601 West Broadway, Louisville, KY 40202 · Other General Government Support · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
600 Martin Luther King Jr. Place Suite 273, Louisville, KY 40202 · Lessors of Other Real Estate Property · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.22(d)(2) · Walking-working surfaces |
Serious | $0 | $0 | Sep 26, 2019 | Final |
| Citation 1, item 2 29 CFR 1910.29(f)(3) · Fall protection systems in general industry |
Serious | $0 | $0 | Sep 26, 2019 | Final |
| Citation 1, item 3 29 CFR 1910.29(f)(7) · Fall protection systems in general industry |
Serious | $0 | $0 | Sep 26, 2019 | Final |
| Citation 1, item 4 29 CFR 1910.305(j)(1)(i) · Electrical wiring methods |
Serious | $0 | $0 | Sep 26, 2019 | Final |
| Citation 1, item 5 | Serious | $0 | $0 | Sep 26, 2019 | Final |
| Citation 2, item 1 | Other-than-serious | $0 | $0 | Sep 26, 2019 | Final |
Current text from the Code of Federal Regulations. Some citations were issued under older wording.
29 CFR 1910.22(d)(2)
(2) Hazardous conditions on walking-working surfaces are corrected or repaired before an employee uses the walking-working surface again. If the correction or repair cannot be made immediately, the hazard must be guarded to prevent employees from using the walking-working surface until the hazard is corrected or repaired; and
29 CFR 1910.29(f)(3)
(3) Surfaces. Handrails and stair rail systems are smooth-surfaced to protect employees from injury, such as punctures or lacerations, and to prevent catching or snagging of clothing.
29 CFR 1910.29(f)(7)
(7) Strength criteria. Handrails and the top rails of stair rail systems are capable of withstanding, without failure, a force of at least 200 pounds (890 N) applied in any downward or outward direction within 2 inches (5 cm) of any point along the top edge of the rail.