OSHA SearchOSHA records by employer

General Services Contractors, Inc.: OSHA inspections and violations

Colorado Springs, Colorado · Site Preparation Contractors · NAICS 238910

3inspections
11citation items
$19,805current penalties
Mar 27, 2019last inspection

Since 2003, OSHA inspectors have visited General Services Contractors, Inc. in Colorado 3 times.

The most recent inspection opened on Mar 27, 2019 as a planned inspection, in Colorado Springs.

In all, OSHA issued 11 citation items: 10 serious and 1 willful.

The proposed penalties came to $40,990; today they stand at $19,805, 52% less.

The rule cited most here is 1926.651 (excavations), 7 times.

Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. General Services Contractors, Inc. averages $16,670 across 1 cited inspection.

General Services Contractors, Inc.: OSHA citation items per year, 2003 to 2019
Citation items per year, by inspection date.

Colorado · latest 90 days of OSHA records

142employers cited

2 of them in the same industry

Get notified the morning OSHA posts each new citation in Colorado: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Colorado

Checking a subcontractor, a client or your own company? Watch General Services Contractors, Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 343964623 OPENED MAR 27, 2019Closed

Planned · Partial · Safety · 3 employees at the site · Closed Nov 3, 2020

230 Balmoral Way, Colorado Springs, CO 80906 · Water and Sewer Line and Related Structures Construction · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.651(c)(2) · Excavations
Serious$2,842$1,421May 8, 2019Final
Citation 1, item 2 Serious$3,978$1,989May 8, 2019Final
Citation 2, item 1
29 CFR 1926.652(a)(1) · Trench protection
Willful$26,520$13,260May 8, 2019Final

Inspection 315017871 OPENED JAN 6, 2011Closed

Complaint · Partial · Safety · 3 employees at the site · Closed Apr 11, 2011

1330 W Cucharras, 13721ado Springs, CO 80904 · Site Preparation Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 2a
29 CFR 1926.652(a)(1) · Trench protection
Serious$4,200$2,100Jan 18, 2011Closed
Citation 1, item 2b
29 CFR 1926.651(i)(1) · Excavations
Serious$0$0Jan 18, 2011Closed
Citation 1, item 2c
29 CFR 1926.651(j)(2) · Excavations
Serious$0$0Jan 18, 2011Closed
Citation 1, item 2d
29 CFR 1926.651(k)(1) · Excavations
Serious$0$0Jan 18, 2011Closed

Inspection 306227075 OPENED OCT 14, 2003Closed

Unprogrammed related · Partial · Safety · 5 employees at the site · Closed Nov 21, 2003

5520 Barnes Road, Colorado Springs, CO 80917 · Site Preparation Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.100(a) · Hard hats in construction
Serious$600$180Oct 16, 2003Closed
Citation 1, item 2a
29 CFR 1926.652(a)(1) · Trench protection
Serious$2,100$630Oct 16, 2003Closed
Citation 1, item 2b
29 CFR 1926.651(k)(1) · Excavations
Serious$0$0Oct 16, 2003Closed
Citation 1, item 3
29 CFR 1926.651(c)(2) · Excavations
Serious$750$225Oct 16, 2003Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.100 · Hard hats in construction

29 CFR 1926.100(a)

(a) Employees working in areas where there is a possible danger of head injury from impact, or from falling or flying objects, or from electrical shock and burns, shall be protected by protective helmets.

29 CFR 1926.651 · Excavations

29 CFR 1926.651(c)(2)

(2) Means of egress from trench excavations. A stairway, ladder, ramp or other safe means of egress shall be located in trench excavations that are 4 feet (1.22 m) or more in depth so as to require no more than 25 feet (7.62 m) of lateral travel for employees.

29 CFR 1926.651(g)(1)(i)

(i) Where oxygen deficiency (atmospheres containing less than 19.5 percent oxygen) or a hazardous atmosphere exists or could reasonably be expected to exist, such as in excavations in landfill areas or excavations in areas where hazardous substances are stored nearby, the atmospheres in the excavation shall be tested before employees enter excavations greater than 4 feet (1.22 m) in depth.

29 CFR 1926.652 · Trench protection

Other site preparation contractors employers in Colorado

Alert subscribers get notified of each newly cited employer in Colorado the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.