Genesis Home Improvement Inc.: OSHA inspections and violations

Brooklyn, New York · Siding Contractors · NAICS 238170

2inspections
4citation items
$14,044current penalties
Oct 28, 2021last inspection

Since 2021, OSHA inspectors have visited Genesis Home Improvement Inc. in New York 2 times.

The most recent inspection opened on Oct 28, 2021 to follow up on an earlier case, in Brooklyn.

In all, OSHA issued 4 citation items: 4 serious.

The penalties, $14,044 in total, stand where OSHA first set them.

The rule cited most here is 1926.451 (scaffolds, general requirements), 4 times.

Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. Genesis Home Improvement Inc. averages $14,044 across 1 cited inspection.

Genesis Home Improvement Inc.: OSHA citation items per year, 2021 to 2021
Citation items per year, by inspection date.

New York · latest 90 days of OSHA records

360employers cited

5 of them in the same industry

Get notified the morning OSHA posts each new citation in New York: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in New York

Checking a subcontractor, a client or your own company? Watch Genesis Home Improvement Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 345608137 OPENED OCT 28, 2021Closed

Follow-up · Partial · Safety · 1 employee at the site · Closed Mar 24, 2022

1522-1524 New York Avenue, Brooklyn, NY 11210 · Siding Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 345369235 OPENED JUN 17, 2021Open

Unprogrammed other · Partial · Safety · 3 employees at the site · Open

1522-1524 New York Avenue, Brooklyn, NY 11210 · Siding Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(b)(1) · Scaffolds, general requirements
Serious$4,096$4,096Jul 7, 2021Final
Citation 1, item 2
29 CFR 1926.451(c)(3) · Scaffolds, general requirements
Serious$2,926$2,926Jul 7, 2021Final
Citation 1, item 3
29 CFR 1926.451(e)(1) · Scaffolds, general requirements
Serious$2,926$2,926Jul 7, 2021Final
Citation 1, item 4
29 CFR 1926.451(g)(1)(vii) · Scaffolds, general requirements
Serious$4,096$4,096Jul 7, 2021Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(b)(1)

(b) Scaffold platform construction. (1) Each platform on all working levels of scaffolds shall be fully planked or decked between the front uprights and the guardrail supports as follows:

29 CFR 1926.451(c)(3)

(3) Supported scaffold poles, legs, posts, frames, and uprights shall be plumb and braced to prevent swaying and displacement.

29 CFR 1926.451(e)(1)

(1) When scaffold platforms are more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from another scaffold, structure, personnel hoist, or similar surface shall be used. Crossbraces shall not be used as a means of access.