OSHA has inspected Geo Prep Mid-City, Inc. once in Louisiana.

The inspection began on Jun 19, 2025 after a fatality or catastrophe, in Baton Rouge.

That inspection ended with 4 citation items: 4 serious.

Penalties were first proposed at $44,685 and now stand at $30,000, 33% lower after settlements or reviews.

Working near live electrical parts comes up most often in these citations: 4 items under 1910.333.

How that compares: the median penalty per cited inspection for education employers since 2015 is $0, and Geo Prep Mid-City, Inc. averages $30,000 (1 cited inspection).

Geo Prep Mid-City, Inc.: OSHA citation items per year, 2025 to 2025
Citation items per year, by inspection date.

Louisiana · latest 90 days of OSHA records

19employers cited

Get notified the morning OSHA posts each new citation in Louisiana: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Louisiana

Checking a subcontractor, a client or your own company? Watch Geo Prep Mid-City, Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 348322264 OPENED JUN 19, 2025Closed

Fatality or catastrophe · Partial · Safety · 150 employees at the site · Closed Feb 17, 2026

1900 Lobdell Blvd, Baton Rouge, LA 70816 · Educational Support Services · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.333(a)(1) · Working near live electrical parts
Serious$14,895$10,000Dec 17, 2025Final
Citation 1, item 2
29 CFR 1910.333(b)(2)(i) · Working near live electrical parts
Serious$14,895$10,000Dec 17, 2025Final
Citation 1, item 3a
29 CFR 1910.333(b)(2)(ii)(b) · Working near live electrical parts
Serious$14,895$10,000Dec 17, 2025Final
Citation 1, item 3b
29 CFR 1910.333(b)(2)(iii)(a) · Working near live electrical parts
Serious$0$0Dec 17, 2025Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.333 · Working near live electrical parts

29 CFR 1910.333(a)(1)

(1) Deenergized parts. Live parts to which an employee may be exposed shall be deenergized before the employee works on or near them, unless the employer can demonstrate that deenergizing introduces additional or increased hazards or is infeasible due to equipment design or operational limitations. Live parts that operate at less than 50 volts to ground need not be deenergized if there will be no increased exposure to electrical burns or to explosion due to electric arcs.

29 CFR 1910.333(b)(2)(i)

(i) Procedures. The employer shall maintain a written copy of the procedures outlined in paragraph (b)(2) and shall make it available for inspection by employees and by the Assistant Secretary of Labor and his or her authorized representatives.

29 CFR 1910.333(b)(2)(ii)(b)

(B) The circuits and equipment to be worked on shall be disconnected from all electric energy sources. Control circuit devices, such as push buttons, selector switches, and interlocks, may not be used as the sole means for deenergizing circuits or equipment. Interlocks for electric equipment may not be used as a substitute for lockout and tagging procedures.