OSHA SearchOSHA records by employer

George Carpentry and Remodeling Corp.: OSHA inspections and violations

Pawtucket, Rhode Island · Roofing Contractors · NAICS 238160

1inspections
5citation items
$13,135current penalties
Sep 10, 2024last inspection

OSHA has inspected George Carpentry and Remodeling Corp. once in Rhode Island.

The inspection began on Sep 10, 2024 after a complaint, in Pawtucket.

That inspection ended with 5 citation items: 5 serious.

Penalties were first proposed at $13,135 and still stand at $13,135.

Scaffolds, general requirements comes up most often in these citations: 2 items under 1926.451.

How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,080, and George Carpentry and Remodeling Corp. averages $13,135 (1 cited inspection).

George Carpentry and Remodeling Corp.: OSHA citation items per year, 2024 to 2024
Citation items per year, by inspection date.

Rhode Island · latest 90 days of OSHA records

76employers cited

7 of them in the same industry

Get notified the morning OSHA posts each new citation in Rhode Island: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Rhode Island

Checking a subcontractor, a client or your own company? Watch George Carpentry and Remodeling Corp. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 347743106 OPENED SEP 10, 2024Closed

Complaint · Partial · Safety · 7 employees at the site · Closed Dec 5, 2024

111 Freight Street, Pawtucket, RI 02860 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.451(c)(2) · Scaffolds, general requirements
Serious$4,839$4,839Oct 16, 2024Final
Citation 1, item 1b
29 CFR 1926.451(g)(1) · Scaffolds, general requirements
Serious$0$0Oct 16, 2024Final
Citation 1, item 1c
29 CFR 1926.452(j)(2) · Rules for each type of scaffold
Serious$0$0Oct 16, 2024Final
Citation 1, item 2
29 CFR 1926.501(b)(13) · Fall protection in construction
Serious$4,839$4,839Oct 16, 2024Final
Citation 1, item 3
29 CFR 1926.1053(b)(10) · Ladders in construction
Serious$3,457$3,457Oct 16, 2024Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.1053 · Ladders in construction

29 CFR 1926.1053(b)(10)

(10) The top of a non-self-supporting ladder shall be placed with the two rails supported equally unless it is equipped with a single support attachment.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(c)(2)

(2) Supported scaffold poles, legs, posts, frames, and uprights shall bear on base plates and mud sills or other adequate firm foundation.

29 CFR 1926.451(g)(1)

(g) Fall protection. (1) Each employee on a scaffold more than 10 feet (3.1 m) above a lower level shall be protected from falling to that lower level. Paragraphs (g)(1) (i) through (vii) of this section establish the types of fall protection to be provided to the employees on each type of scaffold. Paragraph (g)(2) of this section addresses fall protection for scaffold erectors and dismantlers.