OSHA SearchOSHA records by employer

Georgia Builders, LLC.: OSHA inspections and violations

Washington, District of Columbia · New Multifamily Housing Construction (except For-Sale Builders) · NAICS 236116

4inspections
13citation items
$26,712current penalties
Sep 20, 2022last inspection

OSHA has inspected Georgia Builders, LLC. 4 times in District of Columbia since 2016.

The latest one began on Sep 20, 2022, in Washington.

Those inspections ended with 13 citation items: 13 serious.

Penalties were first proposed at $26,712 and still stand at $26,712.

Scaffolds, general requirements comes up most often in these citations: 3 items under 1926.451.

How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,080, and Georgia Builders, LLC. averages $8,904 (3 cited inspections).

Georgia Builders, LLC.: OSHA citation items per year, 2016 to 2022
Citation items per year, by inspection date.

District of Columbia · latest 90 days of OSHA records

13employers cited

Get notified the morning OSHA posts each new citation in District of Columbia: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in District of Columbia

Checking a subcontractor, a client or your own company? Watch Georgia Builders, LLC. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 346235146 OPENED SEP 20, 2022Closed

Programmed other · Complete · Safety · 4 employees at the site · Closed Mar 15, 2023

1544 Rhode Island Avenue, Ne, Washington, DC 20018 · New Multifamily Housing Construction (except For-Sale Builders) · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 345760748 OPENED FEB 2, 2022Closed

Programmed other · Complete · Safety · 1 employee at the site · Closed Dec 23, 2024

4912 Wisconsin Avenue, Nw, Washington, DC 20016 · New Multifamily Housing Construction (except For-Sale Builders) · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.56(a) · Illumination
Serious$2,486$2,486Aug 1, 2022Final
Citation 1, item 2a
29 CFR 1926.403(d)(1) · Electrical equipment on job sites
Serious$1,865$1,865Aug 1, 2022Final
Citation 1, item 2b
29 CFR 1926.403(h) · Electrical equipment on job sites
Serious$0$0Aug 1, 2022Final
Citation 1, item 2c
29 CFR 1926.404(b)(1)(i) · Ground-fault protection on job sites
Serious$0$0Aug 1, 2022Final
Citation 1, item 2d
29 CFR 1926.405(b)(2) · Job-site wiring
Serious$0$0Aug 1, 2022Final
Citation 1, item 3
29 CFR 1926.701(b) · Concrete and Masonry Construction: general requirements
Serious$2,486$2,486Aug 1, 2022Final
Citation 1, item 4a
29 CFR 1926.1052(b)(2) · Stairways in construction
Serious$2,486$2,486Aug 1, 2022Final
Citation 1, item 4b
29 CFR 1926.1052(c)(1)(i) · Stairways in construction
Serious$0$0Aug 1, 2022Final
Citation 1, item 5
29 CFR 1926.501(b)(13) · Fall protection in construction
Serious$4,351$4,351Aug 1, 2022Final

Inspection 342239100 OPENED JAN 19, 2017Closed

Unprogrammed related · Complete · Safety · 2 employees at the site · Closed Aug 19, 2022

4022 Georgia Ave., Nw, Washington, DC 20011 · New Multifamily Housing Construction (except For-Sale Builders) · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(b)(1) · Scaffolds, general requirements
Serious$2,716$2,716May 25, 2017Final
Citation 1, item 2
29 CFR 1926.451(c)(1)(ii) · Scaffolds, general requirements
Serious$2,716$2,716May 25, 2017Final
Citation 1, item 3
29 CFR 1926.451(e)(1) · Scaffolds, general requirements
Serious$3,803$3,803May 25, 2017Final

Inspection 341952109 OPENED NOV 22, 2016Closed

Planned · Complete · Safety · 4 employees at the site · Closed Jul 14, 2021

4022 Georgia Avenue Nw, Washington, DC 20011 · New Multifamily Housing Construction (except For-Sale Builders) · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(13) · Fall protection in construction
Serious$3,803$3,803Feb 6, 2017Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.1052 · Stairways in construction

29 CFR 1926.1052(b)(2)

(2) Except during stairway construction, foot traffic is prohibited on skeleton metal stairs where permanent treads and/or landings are to be installed at a later date, unless the stairs are fitted with secured temporary treads and landings long enough to cover the entire tread and/or landing area.

29 CFR 1926.1052(c)(1)(i)

(i) At least one handrail; and

29 CFR 1926.403 · Electrical equipment on job sites

29 CFR 1926.403(d)(1)

(d) Mounting and cooling of equipment—(1) Mounting. Electric equipment shall be firmly secured to the surface on which it is mounted. Wooden plugs driven into holes in masonry, concrete, plaster, or similar materials shall not be used.

29 CFR 1926.404 · Ground-fault protection on job sites

29 CFR 1926.405 · Job-site wiring

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.501 · Fall protection in construction

29 CFR 1926.56 · Illumination

29 CFR 1926.701 · Concrete and Masonry Construction: general requirements

Other new multifamily housing construction (except for-sale builders) employers in District of Columbia

Alert subscribers get notified of each newly cited employer in District of Columbia the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.