Inspection 348813726 OPENED MAR 16, 2026Closed
1400 Se Butler Bridge Rd, Toledo, OR 97391 · Paperboard Mills · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
OSHA has inspected Georgia Pacific Toledo LLC 6 times in Oregon since 2012.
The latest one began on Mar 16, 2026 after a fatality or catastrophe, in Toledo.
Those inspections ended with 3 citation items: 3 serious.
Penalties were first proposed at $7,300 and still stand at $7,300.
Working near live electrical parts comes up most often in these citations: 2 items under 1910.333.
How that compares: the median penalty per cited inspection for manufacturing employers since 2015 is $4,500, and Georgia Pacific Toledo LLC averages $3,650 (2 cited inspections).
Oregon · latest 90 days of OSHA records
383employers cited
Get notified the morning OSHA posts each new citation in Oregon: the employer, the site address, the rules broken and the penalty.
See who gets cited nextLatest cited in Oregon
Checking a subcontractor, a client or your own company? Watch Georgia Pacific Toledo LLC and get notified the morning OSHA posts a new citation for it.
Watch this company1400 Se Butler Bridge Rd, Toledo, OR 97391 · Paperboard Mills · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
1400 Se Butler Bridge Rd, Toledo, OR 97391 · Paperboard Mills · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR OAR 437-001-0765(1)-2 |
Serious | $300 | $300 | Jun 22, 2023 | Final |
1400 Se Butler Bridge Rd, Toledo, OR 97391 · Paperboard Mills · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
1400 Se Butler Bridge Rd, Toledo, OR 97391 · Paperboard Mills · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.333(a)(1) · Working near live electrical parts |
Serious | $3,500 | $3,500 | Jun 24, 2015 | Final |
| Citation 1, item 2 29 CFR 1910.333(b)(2)(iv)(b) · Working near live electrical parts |
Serious | $3,500 | $3,500 | Jun 24, 2015 | Final |
1400 Se Butler Bridge Rd, Toledo, OR 97391 · Paperboard Mills · OSHA's record · Phone and website on Google Maps
Incident on Feb 26, 2013: Employee is injured when struck by forklift
At approximately 3:20 a.m. February 26, 2013, an employee was walking from a dri ver lunchroom to his parked vehicle on the loading dock. At this time, a forklif t operator was proceeding to the propane fueling station in the area. The forkli ft operator went from the warehouse down a ramp with an unloaded forklift into t he yard as the employee was walking across the area. The forklift struck the emp loyee. The employee was hospitalized and treated for a fractured head.
No citations from this inspection.
1400 Se Butler Bridge Rd, Toledo, OR 97391 · Paperboard Mills · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Current text from the Code of Federal Regulations. Some citations were issued under older wording.
29 CFR 1910.333(a)(1)
(1) Deenergized parts. Live parts to which an employee may be exposed shall be deenergized before the employee works on or near them, unless the employer can demonstrate that deenergizing introduces additional or increased hazards or is infeasible due to equipment design or operational limitations. Live parts that operate at less than 50 volts to ground need not be deenergized if there will be no increased exposure to electrical burns or to explosion due to electric arcs.
29 CFR 1910.333(b)(2)(iv)(b)
(B) A qualified person shall use test equipment to test the circuit elements and electrical parts of equipment to which employees will be exposed and shall verify that the circuit elements and equipment parts are deenergized. The test shall also determine if any energized condition exists as a result of inadvertently induced voltage or unrelated voltage backfeed even though specific parts of the circuit have been deenergized and presumed to be safe. If the circuit to be tested is over 600 volts, nominal, the test equipment shall be checked for proper operation immediately before and immediately after this test.
Alert subscribers get notified of each newly cited employer in Oregon the morning it is posted. See the alert plans.
Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.