OSHA has inspected Georgios Siding Corp. 2 times in New York since 2011.

The latest one began on Jun 27, 2015 as a planned inspection, in Mineola.

Those inspections ended with 4 citation items: 4 serious.

Penalties were first proposed at $12,400 and now stand at $6,600, 47% lower after settlements or reviews.

Scaffolds, general requirements comes up most often in these citations: 2 items under 1926.451.

How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,080, and Georgios Siding Corp. averages $1,500 (1 cited inspection).

Georgios Siding Corp.: OSHA citation items per year, 2011 to 2015
Citation items per year, by inspection date.

New York · latest 90 days of OSHA records

353employers cited

5 of them in the same industry

Get notified the morning OSHA posts each new citation in New York: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in New York

Checking a subcontractor, a client or your own company? Watch Georgios Siding Corp. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 340737485 OPENED JUN 27, 2015Closed

Planned · Partial · Safety · 4 employees at the site · Closed Aug 10, 2015

Horton Hwy., Mineola, NY 11501 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(13) · Fall protection in construction
Serious$2,200$1,500Jun 29, 2015Final

Inspection 315535351 OPENED JUL 27, 2011Closed

Planned · Partial · Safety · 4 employees at the site · Closed Oct 5, 2011

2347 Westley Rd., Westbury, NY 11590 · Siding Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(f)(6) · Scaffolds, general requirements
Serious$4,200$2,100Sep 19, 2011Closed
Citation 1, item 2
29 CFR 1926.451(g)(1) · Scaffolds, general requirements
Serious$3,000$1,500Sep 19, 2011Closed
Citation 1, item 3
29 CFR 1926.452(j)(2) · Rules for each type of scaffold
Serious$3,000$1,500Sep 19, 2011Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(f)(6)

(6) The clearance between scaffolds and power lines shall be as follows: Scaffolds shall not be erected, used, dismantled, altered, or moved such that they or any conductive material handled on them might come closer to exposed and energized power lines than as follows:

29 CFR 1926.451(g)(1)

(g) Fall protection. (1) Each employee on a scaffold more than 10 feet (3.1 m) above a lower level shall be protected from falling to that lower level. Paragraphs (g)(1) (i) through (vii) of this section establish the types of fall protection to be provided to the employees on each type of scaffold. Paragraph (g)(2) of this section addresses fall protection for scaffold erectors and dismantlers.

29 CFR 1926.452 · Rules for each type of scaffold

29 CFR 1926.452(j)(2)

(2) Poles shall be secured to the structure by rigid triangular bracing or equivalent at the bottom, top, and other points as necessary. When the pump jack has to pass bracing already installed, an additional brace shall be installed approximately 4 feet (1.2 m) above the brace to be passed, and shall be left in place until the pump jack has been moved and the original brace reinstalled.

29 CFR 1926.501 · Fall protection in construction