Inspection 347763104 OPENED SEP 18, 2024Closed
1805 Emir St., Houston, TX 77009 · Siding Contractors · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Gigi's Construction LLC has 2 OSHA inspections on record in Texas, the first in 2024.
OSHA's last visit started on Sep 18, 2024 to follow up on an earlier case, in Houston.
Across those inspections OSHA issued 5 citation items: 4 serious and 1 other-than-serious.
OSHA proposed $11,062 in penalties and the amount has not been reduced.
Most often, OSHA cited 1926.451, scaffolds, general requirements (3 items).
For context, across all construction employers the median penalty per cited inspection since 2015 is $3,080. Gigi's Construction LLC averages $11,062 over 1 cited inspection in that time.
Texas · latest 90 days of OSHA records
393employers cited
7 of them in the same industry
Get notified the morning OSHA posts each new citation in Texas: the employer, the site address, the rules broken and the penalty.
See who gets cited nextLatest cited in Texas
Checking a subcontractor, a client or your own company? Watch Gigi's Construction LLC and get notified the morning OSHA posts a new citation for it.
Watch this company1805 Emir St., Houston, TX 77009 · Siding Contractors · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
1805 Emir St., Houston, TX 77009 · Siding Contractors · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1926.304(d) · Woodworking tools |
Serious | $4,610 | $4,610 | May 1, 2024 | Final |
| Citation 1, item 2a 29 CFR 1926.451(a)(6) · Scaffolds, general requirements |
Serious | $6,452 | $6,452 | May 1, 2024 | Final |
| Citation 1, item 2b 29 CFR 1926.451(b)(2) · Scaffolds, general requirements |
Serious | $0 | $0 | May 1, 2024 | Final |
| Citation 1, item 2c 29 CFR 1926.451(g)(1) · Scaffolds, general requirements |
Serious | $0 | $0 | May 1, 2024 | Final |
| Citation 2, item 1 29 CFR 1926.416(e)(1) · Electrical safety in construction |
Other-than-serious | $0 | $0 | May 1, 2024 | Final |
Current text from the Code of Federal Regulations. Some citations were issued under older wording.
29 CFR 1926.304(d)
(d) Guarding. All portable, power-driven circular saws shall be equipped with guards above and below the base plate or shoe. The upper guard shall cover the saw to the depth of the teeth, except for the minimum arc required to permit the base to be tilted for bevel cuts. The lower guard shall cover the saw to the depth of the teeth, except for the minimum arc required to allow proper retraction and contact with the work. When the tool is withdrawn from the work, the lower guard shall automatically and instantly return to the covering position.
29 CFR 1926.416(e)(1)
(e) Cords and cables. (1) Worn or frayed electric cords or cables shall not be used.
29 CFR 1926.451(a)(6)
(6) Scaffolds shall be designed by a qualified person and shall be constructed and loaded in accordance with that design. Non-mandatory appendix A to this subpart contains examples of criteria that will enable an employer to comply with paragraph (a) of this section.
Alert subscribers get notified of each newly cited employer in Texas the morning it is posted. See the alert plans.
Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.