Inspection 349225920 OPENED OCT 15, 2026Open
4005 S. Clay St., Englewood, CO 80111 · Glass Product Manufacturing Made of Purchased Glass · OSHA's record · Phone and website on Google Maps
No citations from this inspection so far.
Since 2018, OSHA inspectors have visited Glaz-Tech Industries, Inc. in Colorado 3 times.
The most recent inspection opened on Oct 15, 2026 as a planned inspection, in Englewood and is still open.
In all, OSHA issued 17 citation items: 12 serious and 5 other-than-serious.
The proposed penalties came to $41,640; today they stand at $25,848, 38% less.
The rule cited most here is 1910.147 (lockout/tagout), 4 times.
Among manufacturing employers, the typical cited inspection since 2015 ends with a $4,500 penalty. Glaz-Tech Industries, Inc. averages $12,924 across 2 cited inspections.
Glaz-Tech Industries, Inc. also files yearly injury logs with OSHA, summarized below.
Colorado · latest 90 days of OSHA records
130employers cited
Get notified the morning OSHA posts each new citation in Colorado: the employer, the site address, the rules broken and the penalty.
See who gets cited nextLatest cited in Colorado
Checking a subcontractor, a client or your own company? Watch Glaz-Tech Industries, Inc. and get notified the morning OSHA posts a new citation for it.
Watch this companyOSHA records show Glaz-Tech Industries, Inc. at 6 sites in 4 states. Together they've had 10 inspections and $42,534 in current penalties.
We match records by employer name and industry, so these sites are likely the same company, not certainly. Franchises and subsidiaries can file under one name.
Included with any plan: the site-by-site record for all 6 sites, with repeat and willful violations and citations per year for the whole company. Already a subscriber? Sign in.
See plans4005 S. Clay St., Englewood, CO 80111 · Glass Product Manufacturing Made of Purchased Glass · OSHA's record · Phone and website on Google Maps
No citations from this inspection so far.
4005 S. Clay St., Englewood, CO 80111 · Glass Product Manufacturing Made of Purchased Glass · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1a 29 CFR 1910.95(d)(1)(i) · Noise |
Other-than-serious | $10,229 | $7,000 | May 17, 2019 | Final |
| Citation 1, item 1b 29 CFR 1910.95(g)(1) · Noise |
Other-than-serious | $0 | $0 | May 17, 2019 | Final |
| Citation 1, item 1c 29 CFR 1910.95(i)(2)(ii) · Noise |
Other-than-serious | $0 | $0 | May 17, 2019 | Final |
4005 S. Clay St., Englewood, CO 80111 · Glass Product Manufacturing Made of Purchased Glass · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.28(b)(1)(i) · Fall protection in general industry |
Serious | $7,391 | $4,435 | Jan 17, 2019 | Final |
| Citation 1, item 2a 29 CFR 1910.147(c)(4)(ii)(d) · Lockout/tagout |
Serious | $5,543 | $3,326 | Jan 17, 2019 | Final |
| Citation 1, item 2b 29 CFR 1910.147(c)(6)(i) · Lockout/tagout |
Serious | $0 | $0 | Jan 17, 2019 | Final |
| Citation 1, item 2c 29 CFR 1910.147(c)(7)(i)(a) · Lockout/tagout |
Serious | $0 | $0 | Jan 17, 2019 | Final |
| Citation 1, item 2d 29 CFR 1910.147(d)(1) · Lockout/tagout |
Serious | $0 | $0 | Jan 17, 2019 | Final |
| Citation 1, item 3a 29 CFR 1910.212(a)(1) · Machine guarding |
Serious | $5,543 | $3,326 | Jan 17, 2019 | Final |
| Citation 1, item 3b 29 CFR 1910.215(a)(4) · Grinders and abrasive wheels |
Serious | $0 | $0 | Jan 17, 2019 | Final |
| Citation 1, item 3c 29 CFR 1910.215(b)(9) · Grinders and abrasive wheels |
Serious | $0 | $0 | Jan 17, 2019 | Final |
| Citation 1, item 4 29 CFR 1910.219(f)(3) · Belts, pulleys and power-transmission parts |
Serious | $7,391 | $4,435 | Jan 17, 2019 | Final |
| Citation 1, item 5a 29 CFR 1910.305(b)(1)(i) · Electrical wiring methods |
Serious | $5,543 | $3,326 | Jan 17, 2019 | Final |
| Citation 1, item 5b 29 CFR 1910.305(g)(2)(iii) · Electrical wiring methods |
Serious | $0 | $0 | Jan 17, 2019 | Final |
| Citation 1, item 5c 29 CFR 1910.334(a)(2)(ii) · Using electrical equipment |
Serious | $0 | $0 | Jan 17, 2019 | Final |
| Citation 2, item 1 29 CFR 1910.303(b)(2) · Electrical equipment, general requirements |
Other-than-serious | $0 | $0 | Jan 17, 2019 | Final |
| Citation 2, item 2 29 CFR 1910.1200(e)(1)(i) · Hazard communication |
Other-than-serious | $0 | $0 | Jan 17, 2019 | Final |
From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.
In 2025, the Englewood site logged 1 recordable injury or illness among about 30 workers: 3.3 per 100 full-time workers, against a median of 3.1 for its industry.
| Site and year | Workers | Cases | Days-away cases | Rate | Industry median |
|---|---|---|---|---|---|
| Glaz-Tech Denver Englewood · 2025 | 30 | 1 | 0 | 3.3 | 3.1 |
Included with any plan: 9 more yearly logs from these sites, back to 2016, with each site's average rate over its latest three years. Already a subscriber? Sign in.
See plansCurrent text from the Code of Federal Regulations. Some citations were issued under older wording.
29 CFR 1910.1200(e)(1)(i)
(i) A list of the hazardous chemicals known to be present using a product identifier that is referenced on the appropriate safety data sheet (the list may be compiled for the workplace as a whole or for individual work areas); and,
29 CFR 1910.147(c)(4)(ii)(d)
(D) Specific requirements for testing a machine or equipment to determine and verify the effectiveness of lockout devices, tagout devices, and other energy control measures.
29 CFR 1910.147(c)(6)(i)
(6) Periodic inspection. (i) The employer shall conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirements of this standard are being followed.
Alert subscribers get notified of each newly cited employer in Colorado the morning it is posted. See the alert plans.
Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.