OSHA SearchOSHA records by employer

Glenn Industrial Group, LLC: OSHA inspections and violations

Columbus, Georgia · Other Heavy and Civil Engineering Construction · NAICS 237990

1inspections
2citation items
$15,000current penalties
Oct 28, 2020last inspection

Glenn Industrial Group, LLC has one OSHA inspection on record in Georgia.

OSHA opened it on Oct 28, 2020 after a fatality or catastrophe, in Columbus.

From that inspection OSHA issued 2 citation items: 1 serious and 1 other-than-serious.

OSHA proposed $20,480 in penalties. After settlements and reviews the total is $15,000, down 27%.

For context, across all construction employers the median penalty per cited inspection since 2015 is $3,080. Glenn Industrial Group, LLC averages $15,000 over 1 cited inspection in that time.

1 inspection on this page followed a fatal incident.

Glenn Industrial Group, LLC: OSHA citation items per year, 2020 to 2020
Citation items per year, by inspection date.

Georgia · latest 90 days of OSHA records

148employers cited

Get notified the morning OSHA posts each new citation in Georgia: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Georgia

Checking a subcontractor, a client or your own company? Watch Glenn Industrial Group, LLC and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 345001317 OPENED OCT 28, 2020Closed

Fatality or catastrophe · Complete · Safety · 4 employees at the site · Closed Jul 11, 2023

1000 Municiple Marina Rd, Columbus, GA 31904 · Other Heavy and Civil Engineering Construction · OSHA's record · Phone and website on Google Maps

Incident on Oct 27, 2020 (fatal): Employee dies after arm is pulled into pipe during dive

At 2:30 p.m. on October 27, 2020, Employee #1, Coworkers #1 and #2, and their supervisor, divers employed by a civil engineering construction company, were engaged in a diving operation at a lake dam. They were assigned to conduct inspections and repairs to several gates and chains. During a solitary dive with an umbilical supplying breathing gas and video, Employee #1 climbed down a long ladder to the water's surface. He then descended into the water, sliding down the chain with his right hand while feeling the side of the dam face with his left hand to guide his way down. At a depth of approximately 15 to 20 feet, his left hand came into contact with a 10-inch hole in the dam's face that led into a Penstock Pipe. Differential pressure caused the employee's left arm to be sucked into the pipe up to his shoulder. He cried out and then went silent and unresponsive. The dive supervisor attempted several times to communicate with Employee #1 but received no response. The supervisor instructed Coworker #1, the backup diver, to go into the water. Coworker #1, after reaching Employee #1, reported that Employee #1 remained unresponsive with no signs of breathing. Coworker #1 was unable to free him from the pipe. Several dam employees were called to the scene, and one of the dam operators closed a valve which released the diver from the pipe. Coworker #1 brought Employee #1 to the water's surface, where he was attached to the emergency retrieval system, removed from the water, and placed on the main deck where emergency medical technicians were standing by. Employee #1 was transported to the hospital, where he was declared dead. The subsequent investigation reported that mechanical asphyxiation may have been the cause of death. At no time had Employee #1 lost air.

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.269(d)(6)(vii) · Electric power generation, transmission, and distribution
Other-than-serious$13,653$8,173Apr 21, 2021Final
Citation 1, item 2
29 CFR 1910.421(d)(2) · Pre-dive procedures
Serious$6,827$6,827Apr 21, 2021Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.269 · Electric power generation, transmission, and distribution

29 CFR 1910.269(d)(6)(vii)

(vii) Before starting work on machines or equipment that have been locked out or tagged out, the authorized employee shall verify that isolation and deenergizing of the machine or equipment have been accomplished. If normally energized parts will be exposed to contact by an employee while the machine or equipment is deenergized, a test shall be performed to ensure that these parts are deenergized.

29 CFR 1910.421 · Pre-dive procedures

29 CFR 1910.421(d)(2)

(2) Surface and underwater conditions and hazards;

Other other heavy and civil engineering construction employers in Georgia

Alert subscribers get notified of each newly cited employer in Georgia the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.