OSHA SearchOSHA records by employer

Gmes Masonry LLC: OSHA inspections and violations

Richmond, Virginia · Masonry Contractors · NAICS 238140

1inspections
8citation items
$3,270current penalties
Nov 1, 2022last inspection

Gmes Masonry LLC has one OSHA inspection on record in Virginia.

OSHA opened it on Nov 1, 2022 as a planned inspection, in Richmond.

From that inspection OSHA issued 8 citation items: 7 serious and 1 other-than-serious.

OSHA proposed $3,270 in penalties and the amount has not been reduced.

Most often, OSHA cited 1926.451, scaffolds, general requirements (5 items).

For context, across all construction employers the median penalty per cited inspection since 2015 is $3,080. Gmes Masonry LLC averages $3,270 over 1 cited inspection in that time.

Gmes Masonry LLC: OSHA citation items per year, 2022 to 2022
Citation items per year, by inspection date.

Virginia · latest 90 days of OSHA records

248employers cited

11 of them in the same industry

Get notified the morning OSHA posts each new citation in Virginia: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Virginia

Checking a subcontractor, a client or your own company? Watch Gmes Masonry LLC and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 346321334 OPENED NOV 1, 2022Closed

Planned · Partial · Safety · 7 employees at the site · Closed May 12, 2023

805 E Parham Rd, Richmond, VA 23227 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 16VAC25-60-130
Serious$1,635$1,635Mar 15, 2023Final
Citation 1, item 2a
29 CFR 1926.451(b)(1) · Scaffolds, general requirements
Serious$1,635$1,635Mar 15, 2023Final
Citation 1, item 2b
29 CFR 1926.451(c)(2)(ii) · Scaffolds, general requirements
Serious$0$0Mar 15, 2023Final
Citation 1, item 2c
29 CFR 1926.452(c)(3) · Rules for each type of scaffold
Serious$0$0Mar 15, 2023Final
Citation 1, item 2d
29 CFR 1926.451(e)(1) · Scaffolds, general requirements
Serious$0$0Mar 15, 2023Final
Citation 1, item 2e
29 CFR 1926.451(f)(7) · Scaffolds, general requirements
Serious$0$0Mar 15, 2023Final
Citation 1, item 2f
29 CFR 1926.451(g)(1)(vii) · Scaffolds, general requirements
Serious$0$0Mar 15, 2023Final
Citation 2, item 1
29 CFR 1926.501(b)(4)(ii) · Fall protection in construction
Other-than-serious$0$0Mar 15, 2023Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(b)(1)

(b) Scaffold platform construction. (1) Each platform on all working levels of scaffolds shall be fully planked or decked between the front uprights and the guardrail supports as follows:

29 CFR 1926.451(c)(2)(ii)

(ii) Unstable objects shall not be used to support scaffolds or platform units.

29 CFR 1926.451(e)(1)

(1) When scaffold platforms are more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from another scaffold, structure, personnel hoist, or similar surface shall be used. Crossbraces shall not be used as a means of access.

29 CFR 1926.452 · Rules for each type of scaffold

29 CFR 1926.501 · Fall protection in construction