Inspection 313384877 OPENED JUL 21, 2011Closed
Accident · Partial · Safety · 66 employees at the site · Closed Feb 18, 2012
2429 Yates Ave, Commerce, CA 90040 · Spice and Extract Manufacturing · OSHA's record · Phone and website on Google Maps
Incident on Jul 16, 2011: Employee's hand is amputated by flavoring mixer blade
At approximately 12:30 p.m. on July 16, 2011, Employee #1 was performing his dut ies as a production worker for a private, incorporated company, in Commerce, CA, that produced food flavorings and colors for wholesale distribution to the food service industry. Onsite activities included the use of horizontal mixers and b lenders, grinding machines, and industrial trucks. Various ingredients were manu ally poured into mixing equipment, according to the customer's specifications. A pparently, the resulting product was then collected and packaged for distributio n. At the time of the incident, Employee #1 was working in the powder department of the facility and was preparing to mix a batch of powdered flavorings in a Fo od Processing Equipment Company Model Number 814 Horizontal Mixer (Kettle Number 16). As part of the company's quality control procedures, the mixers were swabbe d for allergens, prior to product mixture. This procedure involved using a Hygie na Ultrasnap swab, measuring approximately 6 inches in length, to swab a 6-inch diameter, 8-inch length delivery pipe, located at the bottom of the mixing chamb er. Although this procedure was usually conducted by quality control technicians , Employee #1 stated that he had swabbed mixers approximately five or six times prior to the incident, when requested to do so. On the day of the incident, a qu ality control technician asked Employee #1 to swab the mixer because the quality control technician had not brought his respirator. A respirator was required to enter the mixing room, and Employee #1 did have his respirator on and was alrea dy in the mixing room. With the mixer energized and running, Employee #1 reached into the delivery pipe, with the swab in his right hand. The ribbon mixing blad e caught Employee #1's right hand and amputated it at the wrist. It also disloca ted his right elbow. Employee #1 was hospitalized. Employee #1 stated that he di d not realize the mixer was running because the motor was very quiet, when the m achine is running. The quality control technician also stated that he did not re alize the mixer was running until after the incident, when he observed that Empl oyee #1 was injured and could see the reflection of the turning ribbon mixing bl ade on the open top of the machine. According to Employee #1, the quality contro l technician, the powder department supervisor, and other production workers, th e mixers were not locked and tagged out when conducting the swabbing and cleanin g operations; the power was only disengaged by depressing the stop button on the machine. Cal/OSHA determined that the incident was caused by the horizontal mix er not being properly deenergized and disengaged prior to the swabbing operation and issued an accident related citation to the employer.