Gold Coast Surfaces, Inc: OSHA inspections and violations

Pembroke Pines, Florida · Poured Concrete Foundation and Structure Contractors · NAICS 238110

1inspections
4citation items
$0current penalties
Aug 18, 2016last inspection

OSHA inspectors have visited Gold Coast Surfaces, Inc in Florida one time.

It opened on Aug 18, 2016 after a complaint, in Pembroke Pines.

In all, OSHA issued 4 citation items: 4 other-than-serious.

No penalty came with these citations.

The rule cited most here is 1910.134 (respiratory protection), 4 times.

Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. Gold Coast Surfaces, Inc averages $0 across 1 cited inspection.

Gold Coast Surfaces, Inc: OSHA citation items per year, 2016 to 2016
Citation items per year, by inspection date.

Florida · latest 90 days of OSHA records

321employers cited

7 of them in the same industry

Get notified the morning OSHA posts each new citation in Florida: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Florida

Checking a subcontractor, a client or your own company? Watch Gold Coast Surfaces, Inc and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 341708790 OPENED AUG 18, 2016Closed

Complaint · Partial · Health · 9 employees at the site · Closed Mar 31, 2017

281 Hollybrook Drive, Pembroke Pines, FL 33023 · Poured Concrete Foundation and Structure Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.134(c)(1) · Respiratory protection
Other-than-serious$0$0Feb 13, 2017Final
Citation 1, item 2
29 CFR 1910.134(e)(1) · Respiratory protection
Other-than-serious$0$0Feb 13, 2017Final
Citation 1, item 3
29 CFR 1910.134(f)(2) · Respiratory protection
Other-than-serious$0$0Feb 13, 2017Final
Citation 1, item 4
29 CFR 1910.134(k) · Respiratory protection
Other-than-serious$0$0Feb 13, 2017Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.134 · Respiratory protection

29 CFR 1910.134(c)(1)

(1) The test instrument must have an effective audio-warning device, or a visual-warning device in the form of a screen tracing, that indicates when the test subject fails to hold his or her breath during the test. The test must be terminated and restarted from the beginning when the test subject fails to hold his or her breath during the test. The test subject then may be refitted and retested.

29 CFR 1910.134(e)(1)

(1) General. The employer shall provide a medical evaluation to determine the employee's ability to use a respirator, before the employee is fit tested or required to use the respirator in the workplace. The employer may discontinue an employee's medical evaluations when the employee is no longer required to use a respirator.

29 CFR 1910.134(f)(2)

(2) Deep breathing. In a normal standing position, the subject shall breathe slowly and deeply, taking caution so as not to hyperventilate.

Other poured concrete foundation and structure contractors employers in Florida

Alert subscribers get notified of each newly cited employer in Florida the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.