OSHA SearchOSHA records by employer

Golden Gate Construction, Inc: OSHA inspections and violations

Lancaster, Pennsylvania · New Single-Family Housing Construction (except For-Sale Builders) · NAICS 236115

1inspections
3citation items
$6,000current penalties
Aug 18, 2023last inspection

Golden Gate Construction, Inc has one OSHA inspection on record in Pennsylvania.

OSHA opened it on Aug 18, 2023, in Lancaster, and the case has not closed yet.

From that inspection OSHA issued 3 citation items: 2 serious and 1 other-than-serious.

OSHA proposed $9,678 in penalties. After settlements and reviews the total is $6,000, down 38%.

Most often, OSHA cited 1926.451, scaffolds, general requirements (3 items).

For context, across all construction employers the median penalty per cited inspection since 2015 is $3,080. Golden Gate Construction, Inc averages $6,000 over 1 cited inspection in that time.

Golden Gate Construction, Inc: OSHA citation items per year, 2023 to 2023
Citation items per year, by inspection date.

Pennsylvania · latest 90 days of OSHA records

285employers cited

7 of them in the same industry

Get notified the morning OSHA posts each new citation in Pennsylvania: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Pennsylvania

Checking a subcontractor, a client or your own company? Watch Golden Gate Construction, Inc and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 346924970 OPENED AUG 18, 2023Open

Unprogrammed other · Partial · Safety · 3 employees at the site · Open

2151 State Road, Lancaster, PA 17601 · New Single-Family Housing Construction (except For-Sale Builders) · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(c)(3) · Scaffolds, general requirements
Serious$4,839$3,000Feb 7, 2024Final
Citation 1, item 2
29 CFR 1926.451(g)(4)(iii) · Scaffolds, general requirements
Serious$4,839$3,000Feb 7, 2024Final
Citation 2, item 1
29 CFR 1926.451(g)(4)(vii) · Scaffolds, general requirements
Other-than-serious$0$0Feb 7, 2024Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(c)(3)

(3) Supported scaffold poles, legs, posts, frames, and uprights shall be plumb and braced to prevent swaying and displacement.

29 CFR 1926.451(g)(4)(iii)

(iii) When midrails, screens, mesh, intermediate vertical members, solid panels, or equivalent structural members are used, they shall be installed between the top edge of the guardrail system and the scaffold platform.

29 CFR 1926.451(g)(4)(vii)

(vii) Each toprail or equivalent member of a guardrail system shall be capable of withstanding, without failure, a force applied in any downward or horizontal direction at any point along its top edge of at least 100 pounds (445 n) for guardrail systems installed on single-point adjustable suspension scaffolds or two-point adjustable suspension scaffolds, and at least 200 pounds (890 n) for guardrail systems installed on all other scaffolds.

Other new single-family housing construction (except for-sale builders) employers in Pennsylvania

Alert subscribers get notified of each newly cited employer in Pennsylvania the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.