OSHA SearchOSHA records by employer

Gomez Roofing Co.: OSHA inspections and violations

Sunrise, Florida · Roofing Contractors · NAICS 238160

5inspections
8citation items
$33,684current penalties
Jan 6, 2021last inspection

Gomez Roofing Co. has 5 OSHA inspections on record in Florida, the first in 2012.

OSHA's last visit started on Jan 6, 2021 on a referral, in Lighthouse Point.

Across those inspections OSHA issued 8 citation items: 6 serious and 2 repeat.

OSHA proposed $44,034 in penalties. After settlements and reviews the total is $33,684, down 24%.

Most often, OSHA cited 1926.501, fall protection in construction (3 items).

For context, across all construction employers the median penalty per cited inspection since 2015 is $3,080. Gomez Roofing Co. averages $9,361 over 3 cited inspections in that time.

It reported 2 severe injuries to OSHA since 2015.

Gomez Roofing Co.: OSHA citation items per year, 2012 to 2021
Citation items per year, by inspection date.

Florida · latest 90 days of OSHA records

326employers cited

70 of them in the same industry

Get notified the morning OSHA posts each new citation in Florida: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Florida

Checking a subcontractor, a client or your own company? Watch Gomez Roofing Co. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 345141790 OPENED JAN 6, 2021Closed

Referral · Partial · Safety · 20 employees at the site · Closed Jan 12, 2023

2782 Ne 31 Court, Lighthouse Point, FL 33064 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

Incident on Jan 5, 2021: Employee receives shock from power line, falls from roof

At 1:30 p.m. on January 5, 2021, Employee #1, employed by a roofing company, was installing a metal roof on a residence. A metal roof panel made contact with the overhead electric power line, and the employee sustained an electric shock. The employee fell from the roof, a fall height of approximately 31 feet. He was transported to the hospital, where he was admitted for treatment of injuries that included electric shock burns and back injuries.

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.416(a)(1) · Electrical safety in construction
Serious$5,461$5,461Mar 25, 2021Final
Citation 1, item 2
29 CFR 1926.416(a)(3) · Electrical safety in construction
Serious$5,461$5,461Mar 25, 2021Final

Inspection 343742789 OPENED JAN 25, 2019Closed

Planned · Partial · Safety · 3 employees at the site · Closed Dec 17, 2019

2300 Nw 116th Terr., Coral Springs, FL 33065 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.503(a)(1) · Fall protection training in construction
Serious$4,168$2,501Jan 30, 2019Final
Citation 2, item 1
29 CFR 1926.501(b)(13) · Fall protection in construction
Repeat$18,944$13,261Jan 30, 2019Final

Inspection 340963099 OPENED OCT 5, 2015Closed

Referral · Partial · Safety · 25 employees at the site · Closed Apr 5, 2016

6775 Ne 15th Avenue, Fort Lauderdale, FL 33309 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.1060(a) · Ladder and stairway training
Serious$2,000$1,400Oct 27, 2015Final

Inspection 339606014 OPENED FEB 24, 2014Closed

Planned · Partial · Safety · 7 employees at the site · Closed Mar 5, 2015

400 Se 14th Ave, Pompano Beach, FL 33060 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(13) · Fall protection in construction
Repeat$3,200$3,200May 19, 2014Final

Inspection 315359950 OPENED JAN 19, 2012Closed

Planned · Partial · Safety · 3 employees at the site · Closed Sep 19, 2012

8395 W Oakland Park Blvd, Sunrise, FL 33351 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(10) · Fall protection in construction
Serious$2,400$1,200Jan 31, 2012Closed
Citation 1, item 2
29 CFR 1926.1053(b)(1) · Ladders in construction
Serious$2,400$1,200Jan 31, 2012Closed

Severe injury reports

Employers must report any work-related amputation, in-patient hospitalization or loss of an eye to OSHA within 24 hours. 2 reports on file.

Jan 5, 2021, Lighthouse Point: Hospitalization · electrical burns, unspecified · upper and lower limb(s)

An employee was installing metal roofing for a residential home. The metal z-bar he was using contacted a powerline. The employee was shocked and fell about 10 feet from the home's rooftop. He sustained severe electrical burns to his hands, arms, and legs.

Oct 2, 2015, Fort Lauderdale: Hospitalization · intracranial injuries, unspecified · brain

An employee carrying a bucket of paint up a portable ladder fell approximately 10 to 12 feet when the ladder became displaced. He was hospitalized with head/neck lacerations and possible fractures.

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.1053 · Ladders in construction

29 CFR 1926.1053(b)(1)

(1) When portable ladders are used for access to an upper landing surface, the ladder side rails shall extend at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access; or, when such an extension is not possible because of the ladder's length, then the ladder shall be secured at its top to a rigid support that will not deflect, and a grasping device, such as a grabrail, shall be provided to assist employees in mounting and dismounting the ladder. In no case shall the extension be such that ladder deflection under a load would, by itself, cause the ladder to slip off its support.

29 CFR 1926.1060 · Ladder and stairway training

29 CFR 1926.1060(a)

(a) The employer shall provide a training program for each employee using ladders and stairways, as necessary. The program shall enable each employee to recognize hazards related to ladders and stairways, and shall train each employee in the procedures to be followed to minimize these hazards.

29 CFR 1926.416 · Electrical safety in construction

29 CFR 1926.416(a)(1)

(a) Protection of employees. (1) No employer shall permit an employee to work in such proximity to any part of an electric power circuit that the employee could contact the electric power circuit in the course of work, unless the employee is protected against electric shock by deenergizing the circuit and grounding it or by guarding it effectively by insulation or other means.

29 CFR 1926.501 · Fall protection in construction

29 CFR 1926.503 · Fall protection training in construction

Other roofing contractors employers in Florida

Alert subscribers get notified of each newly cited employer in Florida the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.