OSHA SearchOSHA records by employer

Gonzalez Roofing: OSHA inspections and violations

Coppell, Texas · Roofing Contractors · NAICS 238160

5inspections
12citation items
$12,037current penalties
Oct 17, 2024last inspection

Since 1990, OSHA inspectors have visited Gonzalez Roofing in Texas 5 times.

The most recent inspection opened on Oct 17, 2024 on a referral, in Waco and is still open.

In all, OSHA issued 12 citation items: 10 serious and 2 other-than-serious.

The proposed penalties came to $14,461; today they stand at $12,037, 17% less.

The rule cited most here is 1926.501 (fall protection in construction), 3 times.

Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. Gonzalez Roofing averages $4,949 across 2 cited inspections.

Gonzalez Roofing: OSHA citation items per year, 1990 to 2024
Citation items per year, by inspection date.

Want to know if OSHA cites Gonzalez Roofing again? Add it to a watchlist and we will email you the morning the citation shows up.

Watch this company

Inspection history

Inspection 347822298 OPENED OCT 17, 2024Open

Referral · Partial · Safety · 8 employees at the site · Open

Tymco Industries 225 Industrial East, Waco, TX 76705 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(4)(i) · Fall protection in construction
Serious$4,965$4,965Mar 6, 2025Final
Citation 1, item 2
29 CFR 1926.501(b)(10) · Fall protection in construction
Serious$3,547$3,547Mar 6, 2025Final

Inspection 342315603 OPENED MAY 10, 2017Closed

Planned · Complete · Safety · 5 employees at the site · Closed Oct 19, 2017

1357 E League City Pkwy, League City, TX 77573 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.1053(b)(1) · Ladders in construction
Serious$2,309$1,385Jul 6, 2017Final
Citation 1, item 1b
29 CFR 1926.1053(b)(8) · Ladders in construction
Serious$0$0Jul 6, 2017Final

Inspection 315696534 OPENED JUL 15, 2011Closed

Planned · Partial · Safety · 3 employees at the site · Closed Mar 12, 2013

7252 Mansions, Corpus Christi, TX 78414 · New Multifamily Housing Construction (except For-Sale Builders) · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(13) · Fall protection in construction
Serious$3,000$1,500Nov 4, 2011Closed

Inspection 307003251 OPENED JAN 28, 2004Closed

Programmed other · No inspection · Health · 1 employee at the site · Closed Feb 4, 2004

8800 Amarillo Boulevard, Amarillo, TX 79121 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 107544066 OPENED OCT 24, 1990Closed

Planned · Complete · Safety · 6 employees at the site · Closed Apr 23, 1992

300 Mockingbird Ln., Coppell, TX 75019 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.100(a) · Hard hats in construction
Serious$160$160Dec 12, 1990Closed
Citation 1, item 2
29 CFR 1926.405(a)(2)(iij) · Job-site wiring
Serious$160$160Dec 12, 1990Closed
Citation 1, item 3
29 CFR 1926.403(b)(1) · Electrical equipment on job sites
Serious$160$160Dec 12, 1990Closed
Citation 1, item 4a
29 CFR 1926.450(a)(9) · Scope, application and definitions applicable to this subpart
Serious$160$160Dec 12, 1990Closed
Citation 1, item 4b
29 CFR 1926.450(a)(10) · Scope, application and definitions applicable to this subpart
Serious$0$0Dec 12, 1990Closed
Citation 2, item 1
29 CFR 1926.152(a)(1) · Flammable liquids
Other-than-serious$0$0Dec 12, 1990Closed
Citation 2, item 2
29 CFR 1926.405(g)(2)(iii) · Job-site wiring
Other-than-serious$0$0Dec 12, 1990Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.100 · Hard hats in construction

29 CFR 1926.100(a)

(a) Employees working in areas where there is a possible danger of head injury from impact, or from falling or flying objects, or from electrical shock and burns, shall be protected by protective helmets.

29 CFR 1926.1053 · Ladders in construction

29 CFR 1926.1053(b)(1)

(1) When portable ladders are used for access to an upper landing surface, the ladder side rails shall extend at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access; or, when such an extension is not possible because of the ladder's length, then the ladder shall be secured at its top to a rigid support that will not deflect, and a grasping device, such as a grabrail, shall be provided to assist employees in mounting and dismounting the ladder. In no case shall the extension be such that ladder deflection under a load would, by itself, cause the ladder to slip off its support.

29 CFR 1926.1053(b)(8)

(8) Ladders placed in any location where they can be displaced by workplace activities or traffic, such as in passageways, doorways, or driveways, shall be secured to prevent accidental displacement, or a barricade shall be used to keep the activities or traffic away from the ladder.

29 CFR 1926.152 · Flammable liquids

29 CFR 1926.403 · Electrical equipment on job sites

29 CFR 1926.405 · Job-site wiring

29 CFR 1926.450 · Scope, application and definitions applicable to this subpart

29 CFR 1926.501 · Fall protection in construction

Other roofing contractors employers in Texas

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.