OSHA SearchOSHA records by employer

Gooding, Simpson & Mackes, Inc.: OSHA inspections and violations

Elkton, Maryland · Roofing Contractors · NAICS 238160

3inspections
5citation items
$1,427current penalties
Nov 5, 2016last inspection

Gooding, Simpson & Mackes, Inc. has 3 OSHA inspections on record in Maryland, the first in 1987.

OSHA's last visit started on Nov 5, 2016 as a planned inspection, in Bel Air, and the case has not closed yet.

Across those inspections OSHA issued 5 citation items: 2 serious and 3 other-than-serious.

OSHA proposed $1,427 in penalties and the amount has not been reduced.

For context, across all construction employers the median penalty per cited inspection since 2015 is $3,080. Gooding, Simpson & Mackes, Inc. averages $1,137 over 1 cited inspection in that time.

Gooding, Simpson & Mackes, Inc.: OSHA citation items per year, 1987 to 2016
Citation items per year, by inspection date.

Maryland · latest 90 days of OSHA records

185employers cited

32 of them in the same industry

Get notified the morning OSHA posts each new citation in Maryland: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Maryland

Checking a subcontractor, a client or your own company? Watch Gooding, Simpson & Mackes, Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 341898351 OPENED NOV 5, 2016Open

Planned · Complete · Safety · 6 employees at the site · Open

567 Baltimore Pike, Bel Air, MD 21014 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(10) · Fall protection in construction
Serious$1,137$1,137Jan 26, 2017Final
Citation 2, item 1
29 CFR 1926.503(b)(1) · Fall protection training in construction
Other-than-serious$0$0Jan 26, 2017Final

Inspection 308002302 OPENED JUL 22, 2004Closed

Planned · Complete · Safety · 4 employees at the site · Closed Jun 16, 2005

New Science Center, 300 Washington Avenue, Chestertown, MD 21620 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 2, item 1 Other-than-serious$0$0Aug 20, 2004Final

Inspection 18843581 OPENED NOV 13, 1987Closed

Planned · Complete · Safety · 12 employees at the site · Closed Jan 4, 1988

125a Blue Ball Road, Elkton, MD 21921 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.300(b)(2) · Tools—Hand and Power: general requirements
Serious$290$290Dec 8, 1987Closed
Citation 2, item 1
29 CFR 890032 H A
Other-than-serious$0$0Dec 8, 1987Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 0912.2303

29 CFR 1926.300 · Tools—Hand and Power: general requirements

29 CFR 1926.300(b)(2)

(2) Belts, gears, shafts, pulleys, sprockets, spindles, drums, fly wheels, chains, or other reciprocating, rotating or moving parts of equipment shall be guarded if such parts are exposed to contact by employees or otherwise create a hazard. Guarding shall meet the requirements as set forth in American National Standards Institute, B15.1-1953 (R1958), Safety Code for Mechanical Power-Transmission Apparatus.

29 CFR 1926.501 · Fall protection in construction

29 CFR 1926.501(b)(10)

(10) Roofing work on Low-slope roofs. Except as otherwise provided in paragraph (b) of this section, each employee engaged in roofing activities on low-slope roofs, with unprotected sides and edges 6 feet (1.8 m) or more above lower levels shall be protected from falling by guardrail systems, safety net systems, personal fall arrest systems, or a combination of warning line system and guardrail system, warning line system and safety net system, or warning line system and personal fall arrest system, or warning line system and safety monitoring system. Or, on roofs 50-feet (15.25 m) or less in width (see appendix A to subpart M of this part), the use of a safety monitoring system alone [i.e. without the warning line system] is permitted.

29 CFR 1926.503 · Fall protection training in construction

29 CFR 1926.503(b)(1)

(b) Certification of training. (1) The employer shall verify compliance with paragraph (a) of this section by preparing a written certification record. The written certification record shall contain the name or other identity of the employee trained, the date(s) of the training, and the signature of the person who conducted the training or the signature of the employer. If the employer relies on training conducted by another employer or completed prior to the effective date of this section, the certification record shall indicate the date the employer determined the prior training was adequate rather than the date of actual training.

Other roofing contractors employers in Maryland

Alert subscribers get notified of each newly cited employer in Maryland the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.