7inspections
26citation items
$24,960current penalties
Feb 23, 2024last inspection

OSHA has inspected Goodloe E. Moore, Incorporated 7 times in Illinois since 1978.

The latest one began on Feb 23, 2024 on a referral, in Danville.

Those inspections ended with 26 citation items: 16 serious and 10 other-than-serious.

Penalties were first proposed at $40,448 and now stand at $24,960, 38% lower after settlements or reviews.

Lockout/tagout comes up most often in these citations: 4 items under 1910.147.

How that compares: the median penalty per cited inspection for manufacturing employers since 2015 is $3,600, and Goodloe E. Moore, Incorporated averages $23,230 (1 cited inspection).

It reported 1 severe injury to OSHA since 2015.

Goodloe E. Moore, Incorporated: OSHA citation items per year, 1978 to 2024
Citation items per year, by inspection date.

Illinois · latest 90 days of OSHA records

413employers cited

Get notified the morning OSHA posts each new citation in Illinois: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Illinois

Checking a subcontractor, a client or your own company? Watch Goodloe E. Moore, Incorporated and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 347301665 OPENED FEB 23, 2024Closed

Referral · Partial · Safety · 48 employees at the site · Closed Jun 3, 2024

1019 Griggs Street, Danville, IL 61832 · All Other Miscellaneous Fabricated Metal Product Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1 Serious$8,067$4,840May 9, 2024Final
Citation 1, item 2
29 CFR 1910.147(c)(6)(i)(a) · Lockout/tagout
Serious$8,067$4,840May 9, 2024Final
Citation 1, item 3
29 CFR 1910.147(c)(7)(i)(a) · Lockout/tagout
Serious$11,292$6,775May 9, 2024Final
Citation 1, item 4
29 CFR 1910.147(d) · Lockout/tagout
Serious$11,292$6,775May 9, 2024Final

Inspection 1238062 OPENED APR 16, 1986Closed

Complaint · Partial · Health · 16 employees at the site · Closed May 19, 1986

2811 N. Vermilion St., Danville, IL 61832 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 101762193 OPENED APR 15, 1986Closed

Complaint · Complete · Safety · 16 employees at the site · Closed May 29, 1986

2811 N. Vermilion St., Danville, IL 61832 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.212(a)(5) · Machine guarding
Serious$250$250May 5, 1986Closed
Citation 1, item 2a
29 CFR 1910.219(d)(1) · Belts, pulleys and power-transmission parts
Serious$300$300May 5, 1986Closed
Citation 1, item 2b
29 CFR 1910.219(e)(1)(i) · Belts, pulleys and power-transmission parts
Serious$0$0May 5, 1986Closed
Citation 1, item 2c
29 CFR 1910.219(e)(3)(i) · Belts, pulleys and power-transmission parts
Serious$0$0May 5, 1986Closed
Citation 1, item 3
29 CFR 1910.242(b) · Hand and power tools
Serious$300$300May 5, 1986Closed
Citation 2, item 1
29 CFR 1910.242(a) · Hand and power tools
Other-than-serious$0$0May 5, 1986Closed
Citation 2, item 2
29 CFR 1910.304(a)(2) · Grounding and circuit protection
Other-than-serious$0$0May 5, 1986Closed
Citation 2, item 3a
29 CFR 1910.1200(g)(2)(vi) · Hazard communication
Other-than-serious$0$0May 5, 1986Closed
Citation 2, item 3b
29 CFR 1910.1200(g)(2)(vii) · Hazard communication
Other-than-serious$0$0May 5, 1986Closed

Inspection 14437156 OPENED JAN 9, 1980Closed

Complaint · Partial · Health · 18 employees at the site · Closed Mar 10, 1984

2811 North Vermilion, Danville, IL 61832 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 14438923 OPENED NOV 21, 1979Closed

Complaint · Partial · Safety · 18 employees at the site · Closed Mar 10, 1984

2811 N Vermilion, Danville, IL 61832 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 14458376 OPENED OCT 24, 1978Closed

Follow-up · Partial · Health · 22 employees at the site · Closed Mar 10, 1984

2211 N Vermilion, Danville, IL 61232 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 14458780 OPENED APR 17, 1978Closed

Complaint · Partial · Health · 26 employees at the site · Closed Nov 17, 1978

28th N Vermillion, Danville, IL 61832 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a Serious$160$160May 3, 1978Closed
Citation 1, item 1b Serious$0$0May 3, 1978Closed
Citation 1, item 1c Serious$0$0May 3, 1978Closed
Citation 1, item 2
29 CFR 1910.106(d)(4)(i) · Flammable liquids
Serious$240$240May 3, 1978Closed
Citation 1, item 3a
29 CFR 1910.106(e)(2)(ivd) · Flammable liquids
Serious$240$240May 3, 1978Closed
Citation 1, item 3b
29 CFR 1910.106(e)(6)(ii) · Flammable liquids
Serious$0$0May 3, 1978Closed
Citation 1, item 4
29 CFR 1910.106(e)(6)(i) · Flammable liquids
Serious$240$240May 3, 1978Closed
Citation 2, item 1
29 CFR 1910.132(a) · Personal protective equipment, general requirements
Other-than-serious$0$0May 3, 1978Closed
Citation 2, item 2
29 CFR 1910.151(c) · First aid and eyewash
Other-than-serious$0$0May 3, 1978Closed
Citation 2, item 3
29 CFR 1910.212(a)(3)(ii) · Machine guarding
Other-than-serious$0$0May 3, 1978Closed
Citation 3, item 1a
29 CFR 1910.1000(b)(2) · Air contaminants
Other-than-serious$0$0May 18, 1978Closed
Citation 3, item 1b
29 CFR 1910.1000(e) · Air contaminants
Other-than-serious$0$0May 18, 1978Closed
Citation 3, item 1c
29 CFR 1910.134(a)(2) · Respiratory protection
Other-than-serious$0$0May 18, 1978Closed

Severe injury reports

Employers must report any work-related amputation, in-patient hospitalization or loss of an eye to OSHA within 24 hours. 1 report on file.

Feb 15, 2024, Danville: Hospitalization, amputation · amputations, avulsions, enucleations unspecified · other finger(s) n.e.c.

An employee was cleaning a press machine that runs steel coils when their left hand became entangled in the machine. The employee sustained an amputation to their left middle finger and injury to their left ring finger. The machine was not locked out/tagged out at the time.

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.1000 · Air contaminants

29 CFR 1910.1000(b)(2)

(2) Acceptable ceiling concentrations. An employee's exposure to a substance listed in Table Z-2 shall not exceed at any time during an 8-hour shift the acceptable ceiling concentration limit given for the substance in the table, except for a time period, and up to a concentration not exceeding the maximum duration and concentration allowed in the column under “acceptable maximum peak above the acceptable ceiling concentration for an 8-hour shift.”

29 CFR 1910.1000(e)

(e) To achieve compliance with paragraphs (a) through (d) of this section, administrative or engineering controls must first be determined and implemented whenever feasible. When such controls are not feasible to achieve full compliance, protective equipment or any other protective measures shall be used to keep the exposure of employees to air contaminants within the limits prescribed in this section. Any equipment and/or technical measures used for this purpose must be approved for each particular use by a competent industrial hygienist or other technically qualified person. Whenever respirators are used, their use shall comply with 1910.134.

29 CFR 1910.106 · Flammable liquids

29 CFR 1910.106(d)(4)(i)

(4) Design and construction of inside storage rooms—(i) Construction. Inside storage rooms shall be constructed to meet the required fire-resistive rating for their use. Such construction shall comply with the test specifications set forth in Standard Methods of Fire Tests of Building Construction and Materials, NFPA 251-1969. Where an automatic sprinkler system is provided, the system shall be designed and installed in an acceptable manner. Openings to other rooms or buildings shall be provided with noncombustible liquid-tight raised sills or ramps at least 4 inches in height, or the floor in the storage area shall be at least 4 inches below the surrounding floor. Openings shall be provided with approved self-closing fire doors. The room shall be liquid-tight where the walls join the floor. A permissible alternate to the sill or ramp is an open-grated trench inside of the room which dra

29 CFR 1910.1200 · Hazard communication

29 CFR 1910.132 · Personal protective equipment, general requirements

29 CFR 1910.134 · Respiratory protection

29 CFR 1910.147 · Lockout/tagout

29 CFR 1910.151 · First aid and eyewash

29 CFR 1910.212 · Machine guarding

29 CFR 1910.219 · Belts, pulleys and power-transmission parts

29 CFR 1910.242 · Hand and power tools

29 CFR 1910.304 · Grounding and circuit protection

29 CFR 1910.94 · Ventilation

Other all other miscellaneous fabricated metal product manufacturing employers in Illinois

Alert subscribers get notified of each newly cited employer in Illinois the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.