Inspection 341557767 OPENED JUN 10, 2016Closed
160 Prospect Park West, Brooklyn, NY 11215 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Since 2015, OSHA inspectors have visited Gotham Wiring, Inc. in New York 2 times.
The most recent inspection opened on Jun 10, 2016 to follow up on an earlier case, in Brooklyn.
In all, OSHA issued 2 citation items: 2 serious.
The proposed penalties came to $4,800; today they stand at $3,000, 38% less.
Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. Gotham Wiring, Inc. averages $3,000 across 1 cited inspection.
New York · latest 90 days of OSHA records
358employers cited
8 of them in the same industry
Get notified the morning OSHA posts each new citation in New York: the employer, the site address, the rules broken and the penalty.
See who gets cited nextLatest cited in New York
Checking a subcontractor, a client or your own company? Watch Gotham Wiring, Inc. and get notified the morning OSHA posts a new citation for it.
Watch this company160 Prospect Park West, Brooklyn, NY 11215 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
160 Prospect Park West, Brooklyn, NY 11215 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1926.403(i)(2)(i) · Electrical equipment on job sites |
Serious | $2,800 | $1,750 | Oct 22, 2015 | Final |
| Citation 1, item 2 29 CFR 1926.404(b)(1)(i) · Ground-fault protection on job sites |
Serious | $2,000 | $1,250 | Oct 22, 2015 | Final |
Current text from the Code of Federal Regulations. Some citations were issued under older wording.
29 CFR 1926.403(i)(2)(i)
(2) Guarding of live parts. (i) Except as required or permitted elsewhere in this subpart, live parts of electric equipment operating at 50 volts or more shall be guarded against accidental contact by cabinets or other forms of enclosures, or by any of the following means:
29 CFR 1926.404(b)(1)(i)
(b) Branch circuits—(1) Ground-fault protection—(i) General. The employer shall use either ground fault circuit interrupters as specified in paragraph (b)(1)(ii) of this section or an assured equipment grounding conductor program as specified in paragraph (b)(1)(iii) of this section to protect employees on construction sites. These requirements are in addition to any other requirements for equipment grounding conductors.
Alert subscribers get notified of each newly cited employer in New York the morning it is posted. See the alert plans.
Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.