Inspection 342422730 OPENED JUN 22, 2017Closed
512 N Webster, Taylorville, IL 62568 · General Merchandise Stores · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Taylorville, Illinois · General Merchandise Stores · NAICS 452990
Grandview Buildings & Supply, Inc. has 3 OSHA inspections on record in Illinois, the first in 2015.
OSHA's last visit started on Jun 22, 2017 after a complaint, in Taylorville.
Across those inspections OSHA issued 17 citation items: 15 serious, 1 repeat and 1 other-than-serious.
OSHA proposed $31,700 in penalties and the amount has not been reduced.
Most often, OSHA cited 1910.36, exit route design (5 items).
For context, across all retail employers the median penalty per cited inspection since 2015 is $2,140. Grandview Buildings & Supply, Inc. averages $15,850 over 2 cited inspections in that time.
Illinois · latest 90 days of OSHA records
416employers cited
Get notified the morning OSHA posts each new citation in Illinois: the employer, the site address, the rules broken and the penalty.
See who gets cited nextLatest cited in Illinois
Checking a subcontractor, a client or your own company? Watch Grandview Buildings & Supply, Inc. and get notified the morning OSHA posts a new citation for it.
Watch this company512 N Webster, Taylorville, IL 62568 · General Merchandise Stores · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
512 N Webster, Taylorville, IL 62568 · General Merchandise Stores · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.37(a)(4) · Exit routes |
Serious | $2,800 | $2,800 | Mar 7, 2016 | Final |
| Citation 2, item 1 29 CFR 1910.305(b)(2)(i) · Electrical wiring methods |
Repeat | $200 | $200 | Mar 7, 2016 | Final |
| Citation 3, item 1 29 CFR 1910.303(b)(1)(vii) · Electrical equipment, general requirements |
Other-than-serious | $0 | $0 | Mar 7, 2016 | Final |
512 N Webster, Taylorville, IL 62568 · General Merchandise Stores · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1a 29 CFR 1910.22(a)(1) · General requirements |
Serious | $4,200 | $4,200 | Dec 2, 2015 | Final |
| Citation 1, item 1b 29 CFR 1910.22(a)(2) · General requirements |
Serious | $0 | $0 | Dec 2, 2015 | Final |
| Citation 1, item 2 29 CFR 1910.23(a)(8)(ii) · Guarding floor and wall openings and holes |
Serious | $2,100 | $2,100 | Dec 2, 2015 | Final |
| Citation 1, item 3 29 CFR 1910.23(c)(1) · Guarding floor and wall openings and holes |
Serious | $2,800 | $2,800 | Dec 2, 2015 | Final |
| Citation 1, item 4a 29 CFR 1910.36(d)(1) · Exit route design |
Serious | $2,800 | $2,800 | Dec 2, 2015 | Final |
| Citation 1, item 4b 29 CFR 1910.36(d)(2) · Exit route design |
Serious | $0 | $0 | Dec 2, 2015 | Final |
| Citation 1, item 4c 29 CFR 1910.36(d)(3) · Exit route design |
Serious | $0 | $0 | Dec 2, 2015 | Final |
| Citation 1, item 5a 29 CFR 1910.36(g)(2) · Exit route design |
Serious | $2,800 | $2,800 | Dec 2, 2015 | Final |
| Citation 1, item 5b 29 CFR 1910.36(g)(4) · Exit route design |
Serious | $0 | $0 | Dec 2, 2015 | Final |
| Citation 1, item 6 29 CFR 1910.37(b)(2) · Exit routes |
Serious | $2,800 | $2,800 | Dec 2, 2015 | Final |
| Citation 1, item 7 29 CFR 1910.141(a)(4)(i) · Sanitation |
Serious | $4,200 | $4,200 | Dec 2, 2015 | Final |
| Citation 1, item 8 29 CFR 1910.303(f)(1) · Electrical equipment, general requirements |
Serious | $2,100 | $2,100 | Dec 2, 2015 | Final |
| Citation 1, item 9 29 CFR 1910.303(g)(1) · Electrical equipment, general requirements |
Serious | $2,100 | $2,100 | Dec 2, 2015 | Final |
| Citation 1, item 10 29 CFR 1910.305(b)(2)(i) · Electrical wiring methods |
Serious | $2,800 | $2,800 | Dec 2, 2015 | Final |
Current text from the Code of Federal Regulations. Some citations were issued under older wording.
29 CFR 1910.141(a)(4)(i)
(4) Waste disposal. (i) Any receptacle used for putrescible solid or liquid waste or refuse shall be so constructed that it does not leak and may be thoroughly cleaned and maintained in a sanitary condition. Such a receptacle shall be equipped with a solid tight-fitting cover, unless it can be maintained in a sanitary condition without a cover. This requirement does not prohibit the use of receptacles which are designed to permit the maintenance of a sanitary condition without regard to the aforementioned requirements.
29 CFR 1910.303(b)(1)(vii)
(vii) Classification by type, size, voltage, current capacity, and specific use; and
29 CFR 1910.303(f)(1)
(f) Disconnecting means and circuits—(1) Motors and appliances. Each disconnecting means required by this subpart for motors and appliances shall be legibly marked to indicate its purpose, unless located and arranged so the purpose is evident.
Alert subscribers get notified of each newly cited employer in Illinois the morning it is posted. See the alert plans.
Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.