OSHA SearchOSHA records by employer

Granger Masonry Construction, Inc: OSHA inspections and violations

Liverpool, New York · Masonry Contractors · NAICS 238140

5inspections
12citation items
$11,977current penalties
May 30, 2023last inspection

OSHA has inspected Granger Masonry Construction, Inc 5 times in New York since 2005.

The latest one began on May 30, 2023 as a planned inspection, in Cheektowaga.

Those inspections ended with 12 citation items: 11 serious and 1 other-than-serious.

Penalties were first proposed at $22,118 and now stand at $11,977, 46% lower after settlements or reviews.

Scaffolds, general requirements comes up most often in these citations: 9 items under 1926.451.

How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,080, and Granger Masonry Construction, Inc averages $2,854 (4 cited inspections).

Granger Masonry Construction, Inc: OSHA citation items per year, 2005 to 2023
Citation items per year, by inspection date.

New York · latest 90 days of OSHA records

353employers cited

7 of them in the same industry

Get notified the morning OSHA posts each new citation in New York: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in New York

Checking a subcontractor, a client or your own company? Watch Granger Masonry Construction, Inc and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 346761133 OPENED MAY 30, 2023Closed

Planned · Partial · Safety · 2 employees at the site · Closed Aug 11, 2023

2285 Walden Avenue, Cheektowaga, NY 14225 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(g)(1)(vii) · Scaffolds, general requirements
Serious$1,935$1,451Jul 20, 2023Final

Inspection 343540407 OPENED OCT 5, 2018Closed

Planned · Partial · Safety · 6 employees at the site · Closed Nov 20, 2019

2970 West Henrietta Road, Rochester, NY 14623 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(c)(2)(i) · Scaffolds, general requirements
Other-than-serious$2,513$0Nov 8, 2018Final
Citation 1, item 2
29 CFR 1926.451(g)(4)(i) · Scaffolds, general requirements
Serious$2,136$2,000Nov 8, 2018Final
Citation 1, item 3
29 CFR 1926.501(b)(1) · Fall protection in construction
Serious$3,204$2,000Nov 8, 2018Final

Inspection 342052255 OPENED JAN 25, 2017Closed

Planned · Partial · Safety · 5 employees at the site · Closed Apr 5, 2018

5716 S. Transit Road, Lockport, NY 14094 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(e)(1) · Scaffolds, general requirements
Serious$3,259$1,630Feb 9, 2017Final
Citation 1, item 2
29 CFR 1926.451(g)(1)(vii) · Scaffolds, general requirements
Serious$4,346$2,173Feb 9, 2017Final

Inspection 341066546 OPENED NOV 18, 2015Closed

Planned · Partial · Safety · 9 employees at the site · Closed Mar 3, 2016

1569 Niagara Falls Boulevard, Amherst, NY 14226 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(e)(1) · Scaffolds, general requirements
Serious$1,200$720Jan 7, 2016Final
Citation 1, item 2
29 CFR 1926.451(g)(1)(vii) · Scaffolds, general requirements
Serious$2,400$1,440Jan 7, 2016Final

Inspection 307692541 OPENED JUL 21, 2005Closed

Complaint · Partial · Safety · 7 employees at the site · Closed Nov 29, 2005

Electronics Parkway, Liverpool, NY 13088 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(f)(3) · Scaffolds, general requirements
Serious$375$188Aug 2, 2005Final
Citation 1, item 2
29 CFR 1926.451(g)(1) · Scaffolds, general requirements
Serious$375$188Aug 2, 2005Final
Citation 1, item 3a
29 CFR 1926.454(a) · Scaffold training
Serious$375$188Aug 2, 2005Final
Citation 1, item 3b
29 CFR 1926.454(b) · Scaffold training
Serious$0$0Aug 2, 2005Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(c)(2)(i)

(i) Footings shall be level, sound, rigid, and capable of supporting the loaded scaffold without settling or displacement.

29 CFR 1926.451(e)(1)

(1) When scaffold platforms are more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from another scaffold, structure, personnel hoist, or similar surface shall be used. Crossbraces shall not be used as a means of access.

29 CFR 1926.451(f)(3)

(3) Scaffolds and scaffold components shall be inspected for visible defects by a competent person before each work shift, and after any occurrence which could affect a scaffold's structural integrity.

29 CFR 1926.454 · Scaffold training

29 CFR 1926.501 · Fall protection in construction

Other masonry contractors employers in New York

Alert subscribers get notified of each newly cited employer in New York the morning it is posted. See the alert plans.