OSHA SearchOSHA records by employer

Grant Builders, LLC: OSHA inspections and violations

Burlington, Vermont · Residential Remodelers · NAICS 236118

1inspections
5citation items
$1,625current penalties
Dec 8, 2016last inspection

OSHA inspectors have visited Grant Builders, LLC in Vermont one time.

It opened on Dec 8, 2016, in Burlington.

In all, OSHA issued 5 citation items: 5 serious.

The proposed penalties came to $4,000; today they stand at $1,625, 59% less.

The rule cited most here is 1926.405 (job-site wiring), 3 times.

Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. Grant Builders, LLC averages $1,625 across 1 cited inspection.

Grant Builders, LLC: OSHA citation items per year, 2016 to 2016
Citation items per year, by inspection date.

Want to know if OSHA cites Grant Builders, LLC again? Add it to a watchlist and we will email you the morning the citation shows up.

Watch this company

Inspection history

Inspection 341972040 OPENED DEC 8, 2016Closed

Unprogrammed other · Complete · Safety · 1 employee at the site · Closed Jul 24, 2017

56 Ledgemere Street, Burlington, VT 05401 · Residential Remodelers · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 2a
29 CFR 1926.304(i)(1) · Woodworking tools
Serious$2,800$1,025Jan 4, 2017Final
Citation 1, item 2b
29 CFR 1926.304(f) · Woodworking tools
Serious$0$0Jan 4, 2017Final
Citation 1, item 3a
29 CFR 1926.405(b)(2) · Job-site wiring
Serious$1,200$600Jan 4, 2017Final
Citation 1, item 3b
29 CFR 1926.405(a)(2)(ii)(e) · Job-site wiring
Serious$0$0Jan 4, 2017Final
Citation 1, item 3c
29 CFR 1926.405(a)(2)(ii)(f) · Job-site wiring
Serious$0$0Jan 4, 2017Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.304 · Woodworking tools

29 CFR 1926.304(f)

(f) Other requirements. All woodworking tools and machinery shall meet other applicable requirements of American National Standards Institute, 01.1-1961, Safety Code for Woodworking Machinery.

29 CFR 1926.304(i)(1)

(i) Hand-fed ripsaws. (1) Each circular hand-fed ripsaw shall be guarded by a hood which shall completely enclose that portion of the saw above the table and that portion of the saw above the material being cut. The hood and mounting shall be arranged so that the hood will automatically adjust itself to the thickness of and remain in contact with the material being cut but it shall not offer any considerable resistance to insertion of material to saw or to passage of the material being sawed. The hood shall be made of adequate strength to resist blows and strains incidental to reasonable operation, adjusting, and handling, and shall be so designed as to protect the operator from flying splinters and broken saw teeth. It shall be made of material that is soft enough so that it will be unlikely to cause tooth breakage. The hood shall be so mounted as to insure that its operation will be po

29 CFR 1926.405 · Job-site wiring

29 CFR 1926.405(a)(2)(ii)(e)

(E) All lamps for general illumination shall be protected from accidental contact or breakage. Metal-case sockets shall be grounded.