Inspection 347436602 OPENED APR 24, 2024Closed
Corner Of Appleblossom & Pilliod, Holland, OH 43528 · Water and Sewer Line and Related Structures Construction · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
OSHA has inspected Great Lakes Excavating Inc 6 times in Ohio since 2002.
The latest one began on Apr 24, 2024 as a planned inspection, in Holland.
Those inspections ended with 5 citation items: 2 serious, 2 willful and 1 other-than-serious.
Penalties were first proposed at $46,832 and now stand at $21,672, 54% lower after settlements or reviews.
Trench protection comes up most often in these citations: 3 items under 1926.652.
How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,080, and Great Lakes Excavating Inc averages $1,422 (1 cited inspection).
Ohio · latest 90 days of OSHA records
260employers cited
Get notified the morning OSHA posts each new citation in Ohio: the employer, the site address, the rules broken and the penalty.
See who gets cited nextLatest cited in Ohio
Checking a subcontractor, a client or your own company? Watch Great Lakes Excavating Inc and get notified the morning OSHA posts a new citation for it.
Watch this companyCorner Of Appleblossom & Pilliod, Holland, OH 43528 · Water and Sewer Line and Related Structures Construction · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
1475 Arrowhead Road, Maumee, OH 43537 · Site Preparation Contractors · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
7220 Dutch Rd., Waterville, OH 43566 · Water and Sewer Line and Related Structures Construction · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1926.652(a)(1) · Trench protection |
Serious | $2,032 | $1,422 | Mar 31, 2017 | Final |
Fremont Pike And Simmons, Perrysburg, OH 43551 · Site Preparation Contractors · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
1752 Holloway Rd., Holland, OH 43528 · Water and Sewer Line and Related Structures Construction · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1926.651(c)(2) · Excavations |
Other-than-serious | $800 | $250 | Sep 17, 2008 | Final |
| Citation 2, item 1 29 CFR 1926.652(a)(1) · Trench protection |
Willful | $14,000 | $9,000 | Sep 17, 2008 | Final |
Wynnn Rd. Between Navarre & Pickle, Oregon, OH 43605 · Site Preparation Contractors · OSHA's record · Phone and website on Google Maps
Incident on Oct 31, 2002: Employee buried in collapsed trench
On October 31, 2002, Employee #1 and several coworkers were installing a 13-foot -long section of an 8-inch sewer main to a subdivision. The excavation was 11 fe et deep. Classification of the soil was not made and appropriate protective syst ems were not used. While Employee #1 was in the 11-foot-deep excavation dug thro ugh a roadbed, the road bed caved-in and buried Employee #1 to his neck. Employe e #1 sustained multiple contusions as well as a fractured leg and was hospitaliz ed.
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1926.651(k)(1) · Excavations |
Serious | $2,000 | $800 | Feb 3, 2003 | Closed |
| Citation 2, item 1 29 CFR 1926.652(a)(1) · Trench protection |
Willful | $28,000 | $10,200 | Feb 3, 2003 | Closed |
Current text from the Code of Federal Regulations. Some citations were issued under older wording.
29 CFR 1926.651(c)(2)
(2) Means of egress from trench excavations. A stairway, ladder, ramp or other safe means of egress shall be located in trench excavations that are 4 feet (1.22 m) or more in depth so as to require no more than 25 feet (7.62 m) of lateral travel for employees.
29 CFR 1926.651(k)(1)
(k) Inspections. (1) Daily inspections of excavations, the adjacent areas, and protective systems shall be made by a competent person for evidence of a situation that could result in possible cave-ins, indications of failure of protective systems, hazardous atmospheres, or other hazardous conditions. An inspection shall be conducted by the competent person prior to the start of work and as needed throughout the shift. Inspections shall also be made after every rainstorm or other hazard increasing occurrence. These inspections are only required when employee exposure can be reasonably anticipated.
29 CFR 1926.652(a)(1)
(a) Protection of employees in excavations. (1) Each employee in an excavation shall be protected from cave-ins by an adequate protective system designed in accordance with paragraph (b) or (c) of this section except when:
Alert subscribers get notified of each newly cited employer in Ohio the morning it is posted. See the alert plans.
Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.