OSHA SearchOSHA records by employer

Great Lakes TV Seal Inc.: OSHA inspections and violations

Green Bay, Wisconsin · All Other Professional, Scientific, and Technical Services · NAICS 541990

2inspections
17citation items
$20,659current penalties
Jun 8, 2021last inspection

Great Lakes TV Seal Inc. has 2 OSHA inspections on record in Wisconsin, the first in 1989.

OSHA's last visit started on Jun 8, 2021 after a fatality or catastrophe, in Malone.

Across those inspections OSHA issued 17 citation items: 17 serious.

OSHA proposed $20,944 in penalties. After settlements and reviews the total is $20,659, down 1%.

Most often, OSHA cited 1910.146, permit-required confined spaces (5 items).

For context, across all professional services employers the median penalty per cited inspection since 2015 is $1,820. Great Lakes TV Seal Inc. averages $20,284 over 1 cited inspection in that time.

1 inspection on this page followed a fatal incident.

Great Lakes TV Seal Inc. also files yearly injury logs with OSHA, summarized below.

Great Lakes TV Seal Inc.: OSHA citation items per year, 1989 to 2021
Citation items per year, by inspection date.

Wisconsin · latest 90 days of OSHA records

216employers cited

Get notified the morning OSHA posts each new citation in Wisconsin: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Wisconsin

Checking a subcontractor, a client or your own company? Watch Great Lakes TV Seal Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 345350532 OPENED JUN 8, 2021Closed

Fatality or catastrophe · Partial · Health · 3 employees at the site · Closed Feb 11, 2022

N10114 Gulig Road, Malone, WI 53049 · All Other Professional, Scientific, and Technical Services · OSHA's record · Phone and website on Google Maps

Incident on Jun 7, 2021 (fatal): Employee is killed when overexposed to h2s during confined s

At 12:30 p.m. on June 7, 2021, an employee entered a sewer manhole to estimate the amount of materials needed to perform a manhole repair when the employee was overcome by high levels of hydrogen sulfide at the base of the manhole shortly after entry. The employee did not perform atmospheric monitoring and had not donned his harness with rescue tripod before entry into the confined space. A four gas monitor and rescue equipment were located in the employee's work vehicle. Coworker #1 (attendant) and Coworker #2 (helper) were not trained or equipped for performing a confined space entry rescue. A volunteer fire department responded within 8 minutes and performed the confined space entry rescue shortly after arrival. The employee was killed by overexposure to hydrogen sulfide.

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.134(g)(1)(i)(a) · Respiratory protection
Serious$3,901$3,901Nov 29, 2021Final
Citation 1, item 1b
29 CFR 1910.146(d)(3)(vi) · Permit-required confined spaces
Serious$0$0Nov 29, 2021Final
Citation 1, item 1c
29 CFR 1910.1048(d)(2) · Formaldehyde
Serious$0$0Nov 29, 2021Final
Citation 1, item 2a
29 CFR 1910.146(d)(3)(iv) · Permit-required confined spaces
Serious$5,461$5,461Nov 29, 2021Final
Citation 1, item 2b
29 CFR 1910.146(d)(5)(i) · Permit-required confined spaces
Serious$0$0Nov 29, 2021Final
Citation 1, item 2c
29 CFR 1910.1000(b)(2) · Air contaminants
Serious$0$0Nov 29, 2021Final
Citation 1, item 3
29 CFR 1910.146(e)(1) · Permit-required confined spaces
Serious$5,461$5,461Nov 29, 2021Final
Citation 1, item 5
29 CFR 1910.146(k)(3) · Permit-required confined spaces
Serious$5,461$5,461Nov 29, 2021Final

Inspection 103079174 OPENED NOV 28, 1989Closed

Complaint · Complete · Health · 6 employees at the site · Closed Apr 25, 1990

3600 Kewaunee St., Green Bay, WI 54301 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.134(f)(2)(ii) · Respiratory protection
Serious$120$75Feb 21, 1990Closed
Citation 1, item 2a
29 CFR 1910.215(a)(2) · Grinders and abrasive wheels
Serious$120$75Feb 21, 1990Closed
Citation 1, item 2b
29 CFR 1910.215(a)(4) · Grinders and abrasive wheels
Serious$0$0Feb 21, 1990Closed
Citation 1, item 2c
29 CFR 1910.215(b)(9) · Grinders and abrasive wheels
Serious$0$0Feb 21, 1990Closed
Citation 1, item 3a
29 CFR 1910.219(d)(1) · Belts, pulleys and power-transmission parts
Serious$120$75Feb 21, 1990Closed
Citation 1, item 3b
29 CFR 1910.219(e)(3)(i) · Belts, pulleys and power-transmission parts
Serious$0$0Feb 21, 1990Closed
Citation 1, item 4
29 CFR 1910.1200(e)(1) · Hazard communication
Serious$100$50Feb 21, 1990Closed
Citation 1, item 5
29 CFR 1910.1200(g)(1) · Hazard communication
Serious$100$50Feb 21, 1990Closed
Citation 1, item 6
29 CFR 1910.1200(h) · Hazard communication
Serious$100$50Feb 21, 1990Closed

Injury and illness logs

From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.

In 2024, the Green Bay site logged 1 recordable injury or illness among about 21 workers: 4.4 per 100 full-time workers, against a median of 1.0 for its industry.

Site and yearWorkersCasesDays-away casesRateIndustry median
Great Lakes TV Seal Inc.
Green Bay · 2024
21 104.41.0

Included with any plan: 7 more yearly logs from these sites, back to 2017, with each site's average rate over its latest three years. Already a subscriber? Sign in.

See plans

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.1000 · Air contaminants

29 CFR 1910.1000(b)(2)

(2) Acceptable ceiling concentrations. An employee's exposure to a substance listed in Table Z-2 shall not exceed at any time during an 8-hour shift the acceptable ceiling concentration limit given for the substance in the table, except for a time period, and up to a concentration not exceeding the maximum duration and concentration allowed in the column under “acceptable maximum peak above the acceptable ceiling concentration for an 8-hour shift.”

29 CFR 1910.1048 · Formaldehyde

29 CFR 1910.1048(d)(2)

(2) Initial monitoring. The employer shall identify all employees who may be exposed at or above the action level or at or above the STEL and accurately determine the exposure of each employee so identified.

29 CFR 1910.1200 · Hazard communication

29 CFR 1910.1200(e)(1)

(e) Written hazard communication program. (1) Employers shall develop, implement, and maintain at each workplace, a written hazard communication program which at least describes how the criteria specified in paragraphs (f), (g), and (h) of this section for labels and other forms of warning, safety data sheets, and employee information and training will be met, and which also includes the following:

29 CFR 1910.134 · Respiratory protection

29 CFR 1910.146 · Permit-required confined spaces

29 CFR 1910.215 · Grinders and abrasive wheels

29 CFR 1910.219 · Belts, pulleys and power-transmission parts

Other all other professional, scientific, and technical services employers in Wisconsin

Alert subscribers get notified of each newly cited employer in Wisconsin the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.