OSHA SearchOSHA records by employer

Great Southern Building Systems, L.L.C.: OSHA inspections and violations

Kiln, Mississippi · Structural Steel and Precast Concrete Contractors · NAICS 238120

1inspections
3citation items
$79,800current penalties
Sep 8, 2015last inspection

OSHA has inspected Great Southern Building Systems, L.L.C. once in Mississippi.

The inspection began on Sep 8, 2015 as part of a related case, in Kiln; the case is still open.

That inspection ended with 3 citation items: 2 serious and 1 willful.

Penalties were first proposed at $79,800 and still stand at $79,800.

Requirements for cast-in-place concrete comes up most often in these citations: 3 items under 1926.703.

How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,080, and Great Southern Building Systems, L.L.C. averages $79,800 (1 cited inspection).

Great Southern Building Systems, L.L.C.: OSHA citation items per year, 2015 to 2015
Citation items per year, by inspection date.

Mississippi · latest 90 days of OSHA records

23employers cited

Get notified the morning OSHA posts each new citation in Mississippi: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Mississippi

Checking a subcontractor, a client or your own company? Watch Great Southern Building Systems, L.L.C. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 341086197 OPENED SEP 8, 2015Open

Unprogrammed related · Partial · Safety · 5 employees at the site · Open

15152 Highway 603, Kiln, MS 39556 · Structural Steel and Precast Concrete Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.703(a)(2) · Requirements for cast-in-place concrete
Serious$4,900$4,900Mar 2, 2016Final
Citation 1, item 2
29 CFR 1926.703(b)(1) · Requirements for cast-in-place concrete
Serious$4,900$4,900Mar 2, 2016Final
Citation 2, item 1
29 CFR 1926.703(a)(1) · Requirements for cast-in-place concrete
Willful$70,000$70,000Mar 2, 2016Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.703 · Requirements for cast-in-place concrete

29 CFR 1926.703(a)(1)

(a) General requirements for formwork. (1) Formwork shall be designed, fabricated, erected, supported, braced and maintained so that it will be capable of supporting without failure all vertical and lateral loads that may reasonably be anticipated to be applied to the formwork. Formwork which is designed, fabricated, erected, supported, braced and maintained in conformance with the appendix to this section will be deemed to meet the requirements of this paragraph.

29 CFR 1926.703(a)(2)

(2) Drawings or plans, including all revisions, for the jack layout, formwork (including shoring equipment), working decks, and scaffolds, shall be available at the jobsite.

29 CFR 1926.703(b)(1)

(b) Shoring and reshoring. (1) All shoring equipment (including equipment used in reshoring operations) shall be inspected prior to erection to determine that the equipment meets the requirements specified in the formwork drawings.

Other structural steel and precast concrete contractors employers in Mississippi

Alert subscribers get notified of each newly cited employer in Mississippi the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.