OSHA SearchOSHA records by employer

Greaver and Son's Roofing LLC: OSHA inspections and violations

Baltimore, Maryland · Roofing Contractors · NAICS 238160

1inspections
4citation items
$1,125current penalties
Mar 21, 2023last inspection

OSHA inspectors have visited Greaver and Son's Roofing LLC in Maryland one time.

It opened on Mar 21, 2023 as a planned inspection, in Baltimore and is still open.

In all, OSHA issued 4 citation items: 4 serious.

The penalties, $1,125 in total, stand where OSHA first set them.

The rule cited most here is 1926.502 (fall protection systems), 2 times.

Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. Greaver and Son's Roofing LLC averages $1,125 across 1 cited inspection.

Greaver and Son's Roofing LLC: OSHA citation items per year, 2023 to 2023
Citation items per year, by inspection date.

Maryland · latest 90 days of OSHA records

185employers cited

32 of them in the same industry

Get notified the morning OSHA posts each new citation in Maryland: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Maryland

Checking a subcontractor, a client or your own company? Watch Greaver and Son's Roofing LLC and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 346578099 OPENED MAR 21, 2023Open

Planned · Complete · Safety · 3 employees at the site · Open

6010 Clearspring Rd, Baltimore, MD 21212 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.502(d) · Fall protection systems
Serious$750$750May 9, 2023Final
Citation 1, item 1b
29 CFR 1926.502(d)(17) · Fall protection systems
Serious$0$0May 9, 2023Final
Citation 1, item 2a
29 CFR 1926.1053(b)(1) · Ladders in construction
Serious$375$375May 9, 2023Final
Citation 1, item 2b
29 CFR 1926.1053(b)(16) · Ladders in construction
Serious$0$0May 9, 2023Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.1053 · Ladders in construction

29 CFR 1926.1053(b)(1)

(1) When portable ladders are used for access to an upper landing surface, the ladder side rails shall extend at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access; or, when such an extension is not possible because of the ladder's length, then the ladder shall be secured at its top to a rigid support that will not deflect, and a grasping device, such as a grabrail, shall be provided to assist employees in mounting and dismounting the ladder. In no case shall the extension be such that ladder deflection under a load would, by itself, cause the ladder to slip off its support.

29 CFR 1926.1053(b)(16)

(16) Portable ladders with structural defects, such as, but not limited to, broken or missing rungs, cleats, or steps, broken or split rails, corroded components, or other faulty or defective components, shall either be immediately marked in a manner that readily identifies them as defective, or be tagged with “Do Not Use” or similar language, and shall be withdrawn from service until repaired.

29 CFR 1926.502 · Fall protection systems

29 CFR 1926.502(d)

(d) Personal fall arrest systems. Personal fall arrest systems and their use shall comply with the provisions set forth below. Effective January 1, 1998, body belts are not acceptable as part of a personal fall arrest system. Note: The use of a body belt in a positioning device system is acceptable and is regulated under paragraph (e) of this section.

Other roofing contractors employers in Maryland

Alert subscribers get notified of each newly cited employer in Maryland the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.