Grede: OSHA inspections and violations

Meadville, Pennsylvania · Nonferrous Metal Die-Casting Foundries · NAICS 331523

2inspections
5citation items
$20,461current penalties
Jan 8, 2025last inspection

Grede has 2 OSHA inspections on record in Pennsylvania, the first in 2024.

OSHA's last visit started on Jan 8, 2025 on a referral, in Meadville.

Across those inspections OSHA issued 5 citation items: 3 serious and 2 other-than-serious.

OSHA proposed $37,988 in penalties. After settlements and reviews the total is $20,461, down 46%.

For context, across all manufacturing employers the median penalty per cited inspection since 2015 is $3,600. Grede averages $10,231 over 2 cited inspections in that time.

Grede: OSHA citation items per year, 2024 to 2025
Citation items per year, by inspection date.

Want to know if OSHA cites Grede again? Add it to a watchlist and we will email you the morning the citation shows up.

Watch this company

Inspection history

Inspection 347966418 OPENED JAN 8, 2025Closed

Referral · Partial · Health · 225 employees at the site · Closed Aug 20, 2025

18771 Mill Street, Meadville, PA 16335 · Nonferrous Metal Die-Casting Foundries · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.134(f)(2) · Respiratory protection
Serious$7,802$5,461Jul 2, 2025Final

Inspection 347883605 OPENED NOV 15, 2024Closed

Complaint · Partial · Safety · 225 employees at the site · Closed Apr 7, 2025

18771 Mill Street, Meadville, PA 16335 · Nonferrous Metal Die-Casting Foundries · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.147(e)(3) · Lockout/tagout
Serious$16,000$5,000Mar 13, 2025Final
Citation 1, item 2
29 CFR 1910.253(b)(4)(i) · Gas welding and cutting
Serious$7,093$5,000Mar 13, 2025Final
Citation 1, item 3
29 CFR 1910.101(b) · Compressed gases (general requirements)
Other-than-serious$7,093$5,000Mar 13, 2025Final
Citation 2, item 1
29 CFR 1910.106(b)(6) · Flammable liquids
Other-than-serious$0$0Mar 13, 2025Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.101 · Compressed gases (general requirements)

29 CFR 1910.101(b)

(b) Compressed gases. The in-plant handling, storage, and utilization of all compressed gases in cylinders, portable tanks, rail tankcars, or motor vehicle cargo tanks shall be in accordance with Compressed Gas Association Pamphlet P-1-1965, which is incorporated by reference as specified in § 1910.6.

29 CFR 1910.106 · Flammable liquids

29 CFR 1910.134 · Respiratory protection

29 CFR 1910.134(f)(2)

(2) Deep breathing. In a normal standing position, the subject shall breathe slowly and deeply, taking caution so as not to hyperventilate.

29 CFR 1910.147 · Lockout/tagout

29 CFR 1910.147(e)(3)

(3) Lockout or tagout devices removal. Each lockout or tagout device shall be removed from each energy isolating device by the employee who applied the device. Exception to paragraph (e)(3): When the authorized employee who applied the lockout or tagout device is not available to remove it, that device may be removed under the direction of the employer, provided that specific procedures and training for such removal have been developed, documented and incorporated into the employer's energy control program. The employer shall demonstrate that the specific procedure provides equivalent safety to the removal of the device by the authorized employee who applied it. The specific procedure shall include at least the following elements:

29 CFR 1910.253 · Gas welding and cutting